- Insights
- Cold-climate picks
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
All-around best heat pumps by size
Heat pumps that are good at everything, ranked against units their size: half the score is heating (how much heat they keep at 5°F, how efficient they are at 5°F and over a winter), half is cooling (seasonal and hot-day efficiency).
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
All-around best, ducted 5 tons and up
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
395 of 533 models in this size class have all five ratings.
- 1KUMXB601ALG5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 94.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.33 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 18.5 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 227VNA360A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 82.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 3AM060FCMDCG1Samsung5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 83.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.04 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 4VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 83.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.04 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 5H5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCONCarrier (sold as HEIL)Also sold as Comfortmaker C5H3V60*K*AAA, Kenmore (C,H,T)5H3V60*K*AAA, Tempstar T5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 72.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 6AUWR-6024Pwith ducted air handler AUH-6024HisenseAlso listed as AOH-60U3T24P5 tons · 57,000 Btu/h · DuctedCold-climate pick, score 88.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.46 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 19.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.0 (EER2)
- Good
- 727VPA960A*030*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 249VAN060**AA, Arcoaire N5H9V60*K*AAA, Arcoaire Q5H9V60*K*AAA5 tons · 57,500 Btu/h · DuctedCold-climate pick, score 80.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 8H5H8T60*K*AAA*with ducted air handler FTMA5B60L0DCarrier (sold as HEIL)Also sold as Comfortmaker C5H8T60*K*AAA, Kenmore (C,H,T)5H8T60*K*AAA, Tempstar T5H8T60*K*AAA5 tons · 57,500 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.34 (COP at 5°F)
- Top 10%
- Winter efficiency
- 8.1 (HSPF2)
- Good
- Cooling efficiency
- 17.5 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 927TPA860A**30*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 248TAN060**AA, Bryant Heating and Cooling Systems PH8TAN560**AA, HEIL N5H8T60*K*AAA, Grandaire W5H8T60*K*AAA and 1 more; also listed as GH8TAN560**AA5 tons · 57,500 Btu/h · DuctedNot a cold-climate pick: keeps 52% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Top 10%
- Winter efficiency
- 8.1 (HSPF2)
- Good
- Cooling efficiency
- 17.5 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 10MCY-MUB0608HS2P-ULCarrier (sold as Toshiba Carrier)5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 94.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.22 (COP at 5°F)
- Top 10%
- Winter efficiency
- 10.1 (HSPF2)
- Top 10%
- Cooling efficiency
- 18.9 (SEER2)
- Top 10%
- Hot-day cooling
- 10.1 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Want every model’s heating and cooling sub-scores and the all-sizes board? Switch to Advanced
What good looks like: ducted, 5 tons and up
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 53%+
- Great
- 67%+
- Top 10%
- 72%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.20+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 7.2+
- Great
- 9.0+
- Top 10%
- 9.5+
SEER2
Summer-long cooling efficiency
Cooling efficiency over a whole summer, measured with a federal test.
- Good
- 15.8+
- Great
- 17.0+
- Top 10%
- 18.0+
EER2
Hot-day cooling efficiency
Cooling efficiency on a 95°F afternoon.
- Good
- 11.0+
- Great
- 11.7+
- Top 10%
- 12.1+
Next steps
The advanced view adds the all-sizes boards, each qualifier’s peer percentiles, charts of every model in each size class, and the EER2 and heat output boards.
Open the advanced view