Both views use the same certified data. This device remembers your choice.
Ranked by heating power kept at 5°f only
How much of its mild-weather heating power the unit still delivers at 5°F. At 100% the unit puts out as much heat at 5°F as at 47°F in the test. Lower means less heating output in deep cold. This list ranks by that one rating only; the cold-climate picks combine three ratings.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Top 10 by heating power kept at 5°f only: ducted, 3.5 to 4.5 tons
- 1RD18AY60AJVCwith indoor coil (H,R)G52*60+TXV and furnace R962V1155A24M4Rheem4 tons · 50,500 Btu/h · DuctedGreat157%
- 237MUHAQ60AA3with ducted air handler FE*TT4*60+TXVCarrier (sold as Bryant)4 tons · 47,000 Btu/h · DuctedGood142%
- 3RD18AY48AJVCwith indoor coil (H,R)G84*60+TXV and furnace R962V1155A24M4Rheem3.5 tons · 43,000 Btu/h · DuctedTop 10%137%
- 4WFPU17Y483Dwith ducted air handler (V,R)48H175P38*+TXV+TDFriedrich4 tons · 48,000 Btu/h · DuctedBelow the middle136%
- 5RP15AY48AJ2Nwith ducted air handler AE*L+CM48B3J+TDRRheem (sold as RUUD)3.5 tons · 42,500 Btu/h · DuctedTop 10%131%
- 6BOVA-60MTB-M19Ewith ducted air handler AE*L+DM59A4Z+TXV+TDRBosch3.5 tons · 43,500 Btu/h · DuctedTop 10%127%
- 7RP15AY60AJ2Nwith ducted air handler AFM59J+TDRRheem4 tons · 48,000 Btu/h · DuctedTop 10%124%
- 8YH960E2C11with indoor coil AD-62H******+TXV-BLEED and furnace TM8V080C16MP12York4 tons · 47,000 Btu/h · DuctedGreat124%
- 9XH960E2C11with ducted air handler FE*TT4*60+TXVYork (sold as Champion Heating and Cooling)4 tons · 48,000 Btu/h · DuctedGreat122%
- 105TWV8X48A1with indoor coil D(A,C,E)48C3J+TDR and furnace S8V2C080M5PCBTrane4 tons · 45,000 Btu/h · DuctedTop 10%115%
Every ducted, 3.5 to 4.5 tons model, highest first
Top cold-climate picks, ducted 3.5 to 4.5 tons
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 3.5 to 4.5 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 71%+
- Great
- 83%+
- Top 10%
- 98%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.35+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 8.1+
- Great
- 9.0+
- Top 10%
- 10.4+