- Insights
- Cold-climate picks
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ranked by efficiency on a 5°f day only
How much heat the unit makes from each unit of electricity when it is 5°F outside. An electric baseboard heater has a COP of 1, so a COP of 2 means twice the heat from the same electricity in the 5°F test. This list ranks by that one rating. For the units that hold up best in the cold overall, see the cold-climate picks.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
Top 10 by efficiency on a 5°f day only: ducted, 2 tons
- 1UPC24CN23STG1with ducted air handler JHE24B5AC2SS1York (sold as Guardian)2 tons · 24,000 Btu/h · DuctedTop 10%3.55
- 2KUSXA301Awith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons · 21,400 Btu/h · DuctedTop 10%3.43
- 337MURAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 23,400 Btu/h · DuctedTop 10%3.16
- 4NS18H24HA5***with ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons · 22,400 Btu/h · DuctedTop 10%3.13
- 537MUHAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 22,000 Btu/h · DuctedTop 10%3.06
- 6KUSXB301Awith ducted air handler D(A,C,E)31D3D+TDRLG2 tons · 26,000 Btu/h · DuctedTop 10%3.00
- 7248TAN024**AA*with indoor coil C(A,C,D,E)30C3J+TDR and furnace 83*SB48060M17Carrier (sold as Bryant Heating and Cooling Systems)2 tons · 23,000 Btu/h · DuctedTop 10%2.90
- 8D5CUHAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)Also listed as D5CURAH24AAK2 tons · 23,800 Btu/h · DuctedTop 10%2.88
- 95A6H7024A1with ducted air handler CM24D3J+TDRTrane (sold as American Standard)2 tons · 21,000 Btu/h · DuctedTop 10%2.87
- 105TWR7024A1with ducted air handler CM36B4J+TDRTrane2 tons · 21,600 Btu/h · DuctedTop 10%2.85
Every ducted, 2 tons model, highest first
Top cold-climate picks, ducted 2 tons
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Want this size class’s full distribution and peer percentiles? Switch to Advanced
What good looks like: ducted, 2 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 75%+
- Great
- 86%+
- Top 10%
- 96%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.18+
- Top 10%
- 2.43+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 8.8+
- Great
- 9.5+
- Top 10%
- 10.2+
Next steps
The advanced view adds the all-sizes boards, each qualifier’s peer percentiles, charts of every model in each size class, and the EER2 and heat output boards.
Open the advanced view