- Insights
- Cold-climate picks
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ranked by heating power kept at 5°f only
How much of its mild-weather heating power the unit still delivers at 5°F. At 100% the unit puts out as much heat at 5°F as at 47°F in the test. Lower means less heating output in deep cold. This list ranks by that one rating. For the units that hold up best in the cold overall, see the cold-climate picks.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ductless, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
Top 10 by heating power kept at 5°f only: ductless, 2 tons
- 1YRACXJ24WHBAwith ductless indoor unit YRAKXJ24PHBAYork2 tons · 22,000 Btu/h · DuctlessTop 10%123%
- 2YRACXJ24WHAAwith ductless indoor unit YRAKXJ24PHAAYork2 tons · 24,000 Btu/h · DuctlessTop 10%113%
- 3YRACGJ24WHAAwith ductless indoor unit YRAKGJ24PHAAYorkAlso listed as YRACGJ24WHBA2 tons · 22,000 Btu/h · DuctlessTop 10%112%
- 4AM3-H24/2DR3BAUXAlso listed as ASUM24HPMULO2 tons · 24,000 Btu/h · DuctlessTop 10%108%
- 5AOUH24KUAH1with ductless indoor unit ABUH24KUASFujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%107%
- 6YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQYork2 tons · 24,000 Btu/h · DuctlessTop 10%106%
- 7KUSXA241Awith ductless indoor unit KNSCB241ALG2 tons · 24,000 Btu/h · DuctlessTop 10%104%
- 8AOUH24KZAH1with ductless indoor unit ASUH24KZASFujitsu2 tons · 22,000 Btu/h · DuctlessTop 10%102%
- 9AOUH24KWAH3Fujitsu2 tons · 22,000 Btu/h · DuctlessTop 10%101%
- 10RXM24WVJU*with ductless indoor unit FTXM24WVJUDaikin2 tons · 21,600 Btu/h · DuctlessTop 10%100%
Every ductless, 2 tons model, highest first
Top cold-climate picks, ductless 2 tons
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Want this size class’s full distribution and peer percentiles? Switch to Advanced
What good looks like: ductless, 2 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 74%+
- Great
- 83%+
- Top 10%
- 95%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.11+
- Top 10%
- 2.30+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 9.5+
- Great
- 10.0+
- Top 10%
- 11.0+
Next steps
The advanced view adds the all-sizes boards, each qualifier’s peer percentiles, charts of every model in each size class, and the EER2 and heat output boards.
Open the advanced view