- Insights
- Rebate standards
- CEE 2026
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026: which heat pumps meet it?
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 46% of certified models (4,390, about 5 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,096 of 3,130 models67%
- 2 tons760 of 1,437 models53%
- 2.5–3 tons992 of 2,588 models38%
- 3.5–4.5 tons485 of 2,136 models23%
- 5 tons and up57 of 349 models16%
All sizes: 46%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
- 1RHP15048B21with ducted air handler L(E,G)M60A4York (sold as Guardian)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
- 2THF2B48T21with ducted air handler L(E,G)M60A4York (sold as Champion Heating and Cooling)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
- 3YH2F48TB21with ducted air handler AEL+D(A,C,E)60B44+TDRYork3.5 tons · 44,000 Btu/h · DuctedTop 10%3.65
- 44A6C7048A3with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
- 54A6C7048A4with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
- 6RHP15042B21with ducted air handler AEL+D(A,C,E)48B44+TDRYork (sold as Guardian)3.5 tons · 40,000 Btu/h · DuctedTop 10%3.35
- 7THF2B42T21with ducted air handler LEM48C4York (sold as Luxaire)3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
- 8YH2F42TB21with ducted air handler LEM48C4York3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
- 9RP15AZ60AJ2Nwith indoor coil CP61C34+TDR and furnace U802VA125524MRheem (sold as RUUD)4.5 tons · 53,000 Btu/h · DuctedTop 10%3.29
- 10RD17AZ48AJ3Nwith indoor coil D(A,C,E)60C44+TDR and furnace R801V0755A21UHNRheem4 tons · 45,500 Btu/h · DuctedTop 10%3.18
467 ducted, 3.5–4.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view