- Insights
- Rebate standards
- CEE 2026
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026: which heat pumps meet it?
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 46% of certified models (4,390, about 5 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,096 of 3,130 models67%
- 2 tons760 of 1,437 models53%
- 2.5–3 tons992 of 2,588 models38%
- 3.5–4.5 tons485 of 2,136 models23%
- 5 tons and up57 of 349 models16%
All sizes: 46%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
- 1HVAHP060B21S*HITACHI5 tons · 60,000 Btu/h · DuctlessTop 10%2.61
- 2YVAHP060B21S*York5 tons · 60,000 Btu/h · DuctlessTop 10%2.61
- 3FOP1560TJAZNAwith indoor coil FCCN6024SZTA and furnace FF97MV510021DHS*AFujitsu5 tons · 57,000 Btu/h · DuctedTop 10%2.60
- 4MLP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace ML97MV1005A21DHSRheem (sold as Mainline)5 tons · 57,000 Btu/h · DuctedTop 10%2.60
- 5SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHSRheem (sold as SURE)5 tons · 57,000 Btu/h · DuctedTop 10%2.60
- 6WP15AZ60AJ2Nwith indoor coil RCFZ6024STANM and furnace R802VA125524MRheem5 tons · 57,000 Btu/h · DuctedTop 10%2.60
- 7SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHSRUSSELL5 tons · 57,000 Btu/h · DuctedTop 10%2.60
- 8PUMY-P60NKMU3Mitsubishi Electric5 tons · 60,000 Btu/h · DuctedTop 10%2.56
- 9ARUB060GSS4LG5 tons · 60,000 Btu/h · DuctlessTop 10%2.45
- 10MCY-MAP0607HS-UL*Carrier (sold as Toshiba Carrier)5 tons · 60,000 Btu/h · DuctlessGreat2.40
56 ducted, 5 tons and up models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view