CEE 2026: which heat pumps meet it?

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 56% of certified models (7,576, about 6 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,270 of 5,427 models60%
  • 2 tons1,279 of 1,941 models66%
  • 2.5 to 3 tons1,612 of 2,942 models55%
  • 3.5 to 4.5 tons1,264 of 2,834 models45%
  • 5 tons and up151 of 475 models32%

All sizes: 56%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1KUSXA482Awith ducted air handler D(A,C,E)49C3D+TDRLG3.5 tons · 42,500 Btu/h · DuctedTop 10%3.17
  2. 2SL22KLV-060-230A**with indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons · 52,500 Btu/h · DuctedTop 10%3.09
  3. 3RP15AY48AJ2Nwith ducted air handler AE*L+CM59A4J+TDRRheem (sold as RUUD)3.5 tons · 43,000 Btu/h · DuctedTop 10%3.08
  4. 4XH548E2S11with indoor coil D(A,C,E)48D4K+TDR and furnace Z8ET080C16LMPS1York (sold as Champion Heating and Cooling)4 tons · 45,500 Btu/h · DuctedTop 10%3.04
  5. 5HH860E2S12with indoor coil D(A,C,E)61B4K+TDR and furnace Z8ES130D20LMPS1York (sold as Coleman)4 tons · 50,000 Btu/h · DuctedTop 10%3.03
  6. 6248TAN048**AA*with indoor coil C(A,C,D,E)48C3J+TDR and furnace 83*SB60080M21Carrier (sold as Bryant Heating and Cooling Systems)3.5 tons · 44,000 Btu/h · DuctedTop 10%2.93
  7. 7KUSXB481Awith ducted air handler D(A,C,E)48D3D+TDRLG3.5 tons · 42,500 Btu/h · DuctedTop 10%2.92
  8. 85A6H7060A1with ducted air handler D(A,C,E)60B4J+TDRTrane (sold as American Standard)4 tons · 49,500 Btu/h · DuctedTop 10%2.92
  9. 9XH648E2S11with indoor coil D(A,C,E)60A4K+TDR and furnace Z9ES120D20SMPS1York (sold as Coleman)3.5 tons · 44,500 Btu/h · DuctedTop 10%2.91
  10. 1037MUHAQ48AA3with ducted air handler AE*L+CM59A4J+TDRCarrier (sold as Bryant Heating and Cooling Systems)3.5 tons · 44,000 Btu/h · DuctedTop 10%2.90

1,191 ducted, 3.5 to 4.5 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 56%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter