Skip to content

CEE 2026: which heat pumps meet it?

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 56% of certified models (7,576, about 6 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,270 of 5,427 models60%
  • 2 tons1,279 of 1,941 models66%
  • 2.5 to 3 tons1,612 of 2,942 models55%
  • 3.5 to 4.5 tons1,264 of 2,834 models45%
  • 5 tons and up151 of 475 models32%

All sizes: 56%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1AOH-60U3T24Pwith ducted air handler AHU-60U3T24Hisense5 tons · 57,000 Btu/h · DuctedTop 10%2.46
  2. 2AUWR-6024Pwith ducted air handler AUH-6024Hisense5 tons · 57,000 Btu/h · DuctedTop 10%2.46
  3. 3HBEFU-60R454Bwith ducted air handler HBEC-FC60R454BEndura5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  4. 4GRID60OCwith ducted air handler GRID60VAHGridless5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  5. 5HVHDZ-60V2Dwith ducted air handler HAHDZ-60V2DHAXXAIR5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  6. 6MSD-60HD-Bwith ducted air handler 60HMHP0-M-BMulti MFG5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  7. 7SM-60HSM2-CUwith ducted air handler SM-60HSM2-AHSUM X5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  8. 8VAUWR-60HCDR2with ducted air handler VAUH-60HCDR2Voltas5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  9. 9ZE-660HPAwith ducted air handler AH-660AZEPHYR5 tons · 57,000 Btu/h · DuctedTop 10%2.42
  10. 10AOUK060MSAN7Fujitsu5 tons · 60,000 Btu/h · DuctlessTop 10%2.35

151 ducted, 5 tons and up models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 56%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback