Skip to content

CEE 2026: which heat pumps meet it?

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 46% of certified models (4,390, about 5 in 10) meet it.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons2,096 of 3,130 models67%
  • 2 tons760 of 1,437 models53%
  • 2.5–3 tons992 of 2,588 models38%
  • 3.5–4.5 tons485 of 2,136 models23%
  • 5 tons and up57 of 349 models16%

All sizes: 46%

Source: AHRI directory.

Models that meet it, one size class at a time

Highest efficiency on a 5°F day first. Every model here meets the level.
  1. 1ARUN024GSS4LG2 tons · 24,000 Btu/h · DuctlessTop 10%3.59
  2. 2ARUN024GSS4LG2 tons · 24,000 Btu/h · DuctlessTop 10%3.59
  3. 3AOU24RGLXwith ductless indoor unit AUU24RGLXFujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%2.97
  4. 4PUZ-A24NHA7***with ductless indoor unit PLA-A24EAMitsubishi Electric2 tons · 24,000 Btu/h · DuctlessTop 10%2.72
  5. 5TRUZA0241HA70**with ductless indoor unit PLA-A24EAMitsubishi Electric (sold as Trane / Mitsubishi Electric)2 tons · 24,000 Btu/h · DuctlessTop 10%2.72
  6. 6MXZ-3C24NA3***Mitsubishi Electric2 tons · 23,600 Btu/h · DuctedGreat2.55
  7. 7MXZ-3C24NA3***Mitsubishi Electric2 tons · 23,600 Btu/h · DuctedGreat2.55
  8. 8LMU243HVLG2 tons · 24,000 Btu/h · DuctlessTop 10%2.51
  9. 9LMU243HVLG2 tons · 24,000 Btu/h · DuctlessTop 10%2.51
  10. 10RXSQ24TBVJU*Daikin2 tons · 23,000 Btu/h · DuctlessTop 10%2.45

549 ductless, 2 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 46%

Next steps

Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.

Open the advanced view