- Insights
- Rebate standards
- CEE 2026
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CEE 2026: which heat pumps meet it?
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 56% of certified models (6,849, about 6 in 10) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Path A (heating-dominated)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8.5 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9.8 or more
Path B (cooling-dominated / dual fuel)
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
- Winter-long heating efficiency (HSPF2): 8 or more
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 11 or more
Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also have rules about the installer, sizing and paperwork; those are not checked here. Source: Consortium for Energy Efficiency
- Up to 1.5 tons2,869 of 4,712 models61%
- 2 tons1,157 of 1,747 models66%
- 2.5–3 tons1,485 of 2,722 models55%
- 3.5–4.5 tons1,193 of 2,687 models44%
- 5 tons and up145 of 458 models32%
All sizes: 56%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ductless, 2.5–3 tons (27,000–38,999 Btu/h cooling). What size is my system?
- 1KUSXB421Awith ducted air handler D(A,C,E)48D3D+TDRLG3 tons · 38,500 Btu/h · DuctedTop 10%3.11
- 2KUSXA361Awith ducted air handler D(A,C,E)37C3D+TDRLG2.5 tons · 32,400 Btu/h · DuctedTop 10%2.98
- 3MOM27H2XE3AInnovair2.5 tons · 27,000 Btu/h · DuctlessTop 10%2.80
- 4MOM27H2XE3AInnovair2.5 tons · 27,000 Btu/h · DuctlessTop 10%2.80
- 5PUZ-AK36NL***with ductless indoor unit PLA-AE36NLMitsubishi Electric3 tons · 36,000 Btu/h · DuctlessTop 10%2.70
- 6PUZ-AK36NL2***with ductless indoor unit PLA-AE36NLMitsubishi Electric3 tons · 36,000 Btu/h · DuctlessTop 10%2.70
- 7BOHA-36MTB-M18Swith indoor coil D(A,C,E)37D3J+TDR and furnace BGH97M080B3ABosch2.5 tons · 31,600 Btu/h · DuctedTop 10%2.61
- 8BOHA-36MTB-M18Swith indoor coil D(A,C,E)37D3J+TDR and furnace BGH97M080B3ABosch2.5 tons · 31,600 Btu/h · DuctedTop 10%2.61
- 9KUSXB361Awith ducted air handler D(A,C,E)37C3D+TDRLG2.5 tons · 32,400 Btu/h · DuctedTop 10%2.61
- 10M4OD30-36HFN8-M1Midea (sold as MDV)3 tons · 36,000 Btu/h · DuctedTop 10%2.60
1,336 ductless, 2.5–3 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view