Skip to content

CEE 2026: which heat pumps meet it?

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025. 56% of certified models (7,576, about 6 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Path A (heating-dominated)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 65% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8.5 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9.8 or more

Path B (cooling-dominated / dual fuel)

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 50% or more of its 47°F output
  • Winter-long heating efficiency (HSPF2): 8 or more
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 11 or more

Meeting every line of either path is enough. A model counts when at least one of its certified pairings meets every line on its own. Programs can also set rules on the installer, sizing and paperwork; those are not checked. Source: Consortium for Energy Efficiency

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,270 of 5,427 models60%
  • 2 tons1,279 of 1,941 models66%
  • 2.5 to 3 tons1,612 of 2,942 models55%
  • 3.5 to 4.5 tons1,264 of 2,834 models45%
  • 5 tons and up151 of 475 models32%

All sizes: 56%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1KUSXB181Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 16,800 Btu/h · DuctedTop 10%3.17
  2. 2KUSXA181Awith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons · 16,900 Btu/h · DuctedTop 10%3.01
  3. 3KUSXB241Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 20,400 Btu/h · DuctedTop 10%2.95
  4. 4SUZ-AA09NL***with ductless indoor unit MSZ-EX09NLBMitsubishi Electric1 ton · 9,000 Btu/h · DuctlessTop 10%2.93
  5. 5SUZ-AA18NL***with ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons · 18,000 Btu/h · DuctedTop 10%2.93
  6. 6KUSXA241Awith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons · 20,200 Btu/h · DuctedTop 10%2.88
  7. 7SUZ-AA15NL***with ductless indoor unit MSZ-EX15NLBMitsubishi Electric1.5 tons · 15,000 Btu/h · DuctlessTop 10%2.84
  8. 8SUZ-CA15NLH***with ductless indoor unit MFZ-KX15NLMitsubishi Electric1.5 tons · 15,000 Btu/h · DuctlessTop 10%2.79
  9. 9BOHA-24MTB-M18Swith ducted air handler AE*S+CM24C3K+TDRBosch1.5 tons · 20,600 Btu/h · DuctedTop 10%2.73
  10. 10BOHA-24MTB-M18Swith ducted air handler AE*S+CM24C3K+TDRBosch1.5 tons · 20,600 Btu/h · DuctedTop 10%2.73

3,277 ductless, up to 1.5 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 56%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter