- Insights
- Rebate standards
- Xcel CC
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel CC: which heat pumps meet it?
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 38% of certified models (3,627, about 4 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.
- Up to 1.5 tons1,694 of 3,130 models54%
- 2 tons666 of 1,437 models46%
- 2.5–3 tons810 of 2,588 models31%
- 3.5–4.5 tons429 of 2,136 models20%
- 5 tons and up28 of 349 models8%
All sizes: 38%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
- 1ARUN024GSS4LG2 tons · 24,000 Btu/h · DuctlessTop 10%3.59
- 24HP18V36Pwith indoor coil C(A,C,D,E)36B34+TDR and furnace 80G1UH070AE12Lennox (sold as Ducane)2 tons · 22,400 Btu/h · DuctedTop 10%3.19
- 34SHP18LX136Pwith indoor coil D(A,C,E)36A34+TDR and furnace A97USMV070B12Lennox (sold as Armstrong Air)2 tons · 21,800 Btu/h · DuctedTop 10%3.15
- 4RP15AZ24AJ2Nwith indoor coil D(A,C,E)36D24+TDR and furnace R801V1004A17UHNRheem2 tons · 22,200 Btu/h · DuctedTop 10%3.15
- 525SPA524A**30*with indoor coil D(A,C,E)30C44+TDR and furnace 58TP*A045V14**12Carrier2 tons · 23,200 Btu/h · DuctedTop 10%3.12
- 638MURAQ24AB3*with indoor coil D(A,C,E)36B34+TDR and furnace PG96MSAA48060BCarrier (sold as Payne Heating and Cooling)2 tons · 23,600 Btu/h · DuctedTop 10%3.09
- 725SCA524A**30*with indoor coil D(A,C,E)30C44+TDR and furnace 59TP6C100V21**22Carrier2 tons · 23,800 Btu/h · DuctedTop 10%3.04
- 8DLCURAH24ABKwith indoor coil D(A,C,E)30C44+TDR and furnace *92ESN0802120ACarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%3.03
- 9N4H5S24*K*AAA*with indoor coil D(A,C,E)30C44+TDR and furnace *92MSN1002120ACarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%3.02
- 10YZT24B21with ducted air handler AE(D,N,U)+CM36B34+TDRYork2 tons · 21,600 Btu/h · DuctedTop 10%3.01
491 ducted, 2 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view