- Insights
- Rebate standards
- Xcel CC
Both views use the same certified data. This device remembers your choice.
Xcel CC: which heat pumps meet it?
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 38% of certified models (3,739, about 4 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.
- Up to 1.5 tons1,748 of 3,201 models55%
- 2 tons682 of 1,454 models47%
- 2.5 to 3 tons830 of 2,633 models32%
- 3.5 to 4.5 tons449 of 2,174 models21%
- 5 tons and up30 of 362 models8%
All sizes: 38%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
- 1RHP15048B21with ducted air handler L(E,G)M60A4York (sold as Guardian)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
- 2THF2B48T21with ducted air handler L(E,G)M60A4York (sold as Champion Heating and Cooling)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
- 3YH2F48TB21with ducted air handler AEL+D(A,C,E)60B44+TDRYork3.5 tons · 44,000 Btu/h · DuctedTop 10%3.65
- 44A6C7048A3with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
- 54A6C7048A4with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
- 6RHP15042B21with ducted air handler AEL+D(A,C,E)48B44+TDRYork (sold as Guardian)3.5 tons · 40,000 Btu/h · DuctedTop 10%3.35
- 7THF2B42T21with ducted air handler LEM48C4York (sold as Luxaire)3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
- 8YH2F42TB21with ducted air handler LEM48C4York3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
- 9RD17AZ48AJ3Nwith indoor coil D(A,C,E)60C44+TDR and furnace R801V0755A21UHNRheem4 tons · 45,500 Btu/h · DuctedTop 10%3.18
- 10RP15AZ48AJ2Nwith indoor coil CP61B34+TDR and furnace ROCB118V05MRheem (sold as RUUD)3.5 tons · 44,500 Btu/h · DuctedTop 10%3.18
428 ducted, 3.5 to 4.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.
Open the advanced view