Skip to content

Xcel CC: which heat pumps meet it?

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 38% of certified models (3,739, about 4 in 10) meet it.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

What it asks for

Ducted units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 15.2 or more
  • Hot-day cooling efficiency (EER2): 10 or more

Ductless units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9 or more

A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons1,748 of 3,201 models55%
  • 2 tons682 of 1,454 models47%
  • 2.5 to 3 tons830 of 2,633 models32%
  • 3.5 to 4.5 tons449 of 2,174 models21%
  • 5 tons and up30 of 362 models8%

All sizes: 38%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1RHP15048B21with ducted air handler L(E,G)M60A4York (sold as Guardian)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
  2. 2THF2B48T21with ducted air handler L(E,G)M60A4York (sold as Champion Heating and Cooling)4 tons · 45,000 Btu/h · DuctedTop 10%3.70
  3. 3YH2F48TB21with ducted air handler AEL+D(A,C,E)60B44+TDRYork3.5 tons · 44,000 Btu/h · DuctedTop 10%3.65
  4. 44A6C7048A3with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
  5. 54A6C7048A4with ducted air handler 4PX*CU60BS3+P0V0C000M50SCTrane (sold as American Standard)4 tons · 48,000 Btu/h · DuctedTop 10%3.60
  6. 6RHP15042B21with ducted air handler AEL+D(A,C,E)48B44+TDRYork (sold as Guardian)3.5 tons · 40,000 Btu/h · DuctedTop 10%3.35
  7. 7THF2B42T21with ducted air handler LEM48C4York (sold as Luxaire)3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
  8. 8YH2F42TB21with ducted air handler LEM48C4York3.5 tons · 39,000 Btu/h · DuctedTop 10%3.33
  9. 9RD17AZ48AJ3Nwith indoor coil D(A,C,E)60C44+TDR and furnace R801V0755A21UHNRheem4 tons · 45,500 Btu/h · DuctedTop 10%3.18
  10. 10RP15AZ48AJ2Nwith indoor coil CP61B34+TDR and furnace ROCB118V05MRheem (sold as RUUD)3.5 tons · 44,500 Btu/h · DuctedTop 10%3.18

428 ducted, 3.5 to 4.5 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 38%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter