- Insights
- Rebate standards
- Xcel CC
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel CC: which heat pumps meet it?
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 38% of certified models (3,627, about 4 in 10) meet it.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
What it asks for
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.
- Up to 1.5 tons1,694 of 3,130 models54%
- 2 tons666 of 1,437 models46%
- 2.5–3 tons810 of 2,588 models31%
- 3.5–4.5 tons429 of 2,136 models20%
- 5 tons and up28 of 349 models8%
All sizes: 38%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
- 1LUU180HHVwith ducted air handler LDN187HV4LG1.5 tons · 18,000 Btu/h · DuctedTop 10%3.29
- 2NTXSKH09A112**with ducted air handler TPEADA0091AA90AMitsubishi Electric (sold as Trane / Mitsubishi Electric)1 ton · 9,000 Btu/h · DuctedTop 10%3.28
- 3SUZ-KA09NAHZ*with ducted air handler TPEADA0091AA90AMitsubishi Electric (sold as Trane / Mitsubishi Electric)1 ton · 9,000 Btu/h · DuctedTop 10%3.28
- 4YH2F18SB21with ducted air handler AE*S+CM24C24+TDRYork1.5 tons · 15,700 Btu/h · DuctedTop 10%3.09
- 5THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDRYork (sold as Luxaire)1.5 tons · 16,400 Btu/h · DuctedTop 10%3.04
- 638MURAQ18AB3*with indoor coil D(A,C,E)24B44+TDR and furnace 59TP6B040V17**12Carrier1.5 tons · 17,600 Btu/h · DuctedTop 10%2.94
- 7RHP15018B21with ducted air handler L(E,G)M24F4York (sold as Guardian)1.5 tons · 16,700 Btu/h · DuctedTop 10%2.92
- 8EODA18H-2436with ducted air handler AE(D,N,U)+CM30B24+TDREcoer1.5 tons · 20,000 Btu/h · DuctedTop 10%2.82
- 94HP17L18P-**Awith ducted air handler PE(S,T)274Gree (sold as Ac Pro)1.5 tons · 17,200 Btu/h · DuctedTop 10%2.82
- 104HP17L18P-**Awith ducted air handler PE(S,T)274Lennox (sold as Concord)1.5 tons · 17,200 Btu/h · DuctedTop 10%2.82
590 ducted, up to 1.5 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view