Skip to content

Xcel CC: which heat pumps meet it?

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 38% of certified models (3,739, about 4 in 10) meet it.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

What it asks for

Ducted units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 15.2 or more
  • Hot-day cooling efficiency (EER2): 10 or more

Ductless units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9 or more

A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons1,748 of 3,201 models55%
  • 2 tons682 of 1,454 models47%
  • 2.5 to 3 tons830 of 2,633 models32%
  • 3.5 to 4.5 tons449 of 2,174 models21%
  • 5 tons and up30 of 362 models8%

All sizes: 38%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1LUU180HHVwith ducted air handler LDN187HV4LG1.5 tons · 18,000 Btu/h · DuctedTop 10%3.29
  2. 2NTXSKH09A112**with ducted air handler TPEADA0091AA90AMitsubishi Electric (sold as Trane / Mitsubishi Electric)1 ton · 9,000 Btu/h · DuctedTop 10%3.28
  3. 3SUZ-KA09NAHZ*with ducted air handler TPEADA0091AA90AMitsubishi Electric (sold as Trane / Mitsubishi Electric)1 ton · 9,000 Btu/h · DuctedTop 10%3.28
  4. 4YH2F18SB21with ducted air handler AE*S+CM24C24+TDRYork1.5 tons · 15,700 Btu/h · DuctedTop 10%3.09
  5. 5THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDRYork (sold as Luxaire)1.5 tons · 16,400 Btu/h · DuctedTop 10%3.04
  6. 638MURAQ18AB3*with indoor coil D(A,C,E)24B44+TDR and furnace 59TP6B040V17**12Carrier1.5 tons · 17,600 Btu/h · DuctedTop 10%2.94
  7. 7RHP15018B21with ducted air handler L(E,G)M24F4York (sold as Guardian)1.5 tons · 16,700 Btu/h · DuctedTop 10%2.92
  8. 8EODA18H-2436with ducted air handler AE(D,N,U)+CM30B24+TDREcoer1.5 tons · 20,000 Btu/h · DuctedTop 10%2.82
  9. 94HP17L18P-**Awith ducted air handler PE(S,T)274Gree (sold as Ac Pro)1.5 tons · 17,200 Btu/h · DuctedTop 10%2.82
  10. 104HP17L18P-**Awith ducted air handler PE(S,T)274Lennox (sold as Concord)1.5 tons · 17,200 Btu/h · DuctedTop 10%2.82

603 ducted, up to 1.5 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 38%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter