- Insights
- Rebate standards
- Xcel CC
Both views use the same certified data. This device remembers your choice.
Xcel CC: which heat pumps meet it?
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 53% of certified models (7,174, about 5 in 10) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.
- Up to 1.5 tons3,292 of 5,427 models61%
- 2 tons1,152 of 1,941 models59%
- 2.5 to 3 tons1,483 of 2,942 models50%
- 3.5 to 4.5 tons1,195 of 2,834 models42%
- 5 tons and up52 of 475 models11%
All sizes: 53%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
- 1UPC24CN23STG1with ducted air handler JHE24B5AC2SS1York (sold as Guardian)2 tons · 24,000 Btu/h · DuctedTop 10%3.55
- 2KUSXA301Awith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons · 21,400 Btu/h · DuctedTop 10%3.43
- 337MURAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 23,400 Btu/h · DuctedTop 10%3.16
- 4NS18H24HA5***with ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons · 22,400 Btu/h · DuctedTop 10%3.13
- 537MUHAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 22,000 Btu/h · DuctedTop 10%3.06
- 6AOUK024SSAN7Fujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%3.03
- 7KUSXB301Awith ducted air handler D(A,C,E)31D3D+TDRLG2 tons · 26,000 Btu/h · DuctedTop 10%3.00
- 8D5CUHAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
- 9D5CURAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
- 10TZP15AY24AJ2Nwith ducted air handler L(E,F)W30BJTHERMAL ZONE2 tons · 21,800 Btu/h · DuctedTop 10%2.88
722 ducted, 2 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.
Open the advanced view