Skip to content

Xcel CC: which heat pumps meet it?

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 53% of certified models (7,174, about 5 in 10) meet it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

What it asks for

Ducted units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 15.2 or more
  • Hot-day cooling efficiency (EER2): 10 or more

Ductless units

  • Efficiency on a 5°F day (COP at 5°F): 1.75 or more
  • Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
  • Summer-long cooling efficiency (SEER2): 16 or more
  • Hot-day cooling efficiency (EER2): 9 or more

A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.

How often each size meets itThe dark line is the share across all sizes; each bar is one size, every type together.
  • Up to 1.5 tons3,292 of 5,427 models61%
  • 2 tons1,152 of 1,941 models59%
  • 2.5 to 3 tons1,483 of 2,942 models50%
  • 3.5 to 4.5 tons1,195 of 2,834 models42%
  • 5 tons and up52 of 475 models11%

All sizes: 53%

Source: AHRI directory.

Models that meet it, one size class at a time

Sorted by efficiency at 5°F, highest first.
  1. 1UPC24CN23STG1with ducted air handler JHE24B5AC2SS1York (sold as Guardian)2 tons · 24,000 Btu/h · DuctedTop 10%3.55
  2. 2KUSXA301Awith ducted air handler C(A,C,D,E)30C3D+TDRLG2 tons · 21,400 Btu/h · DuctedTop 10%3.43
  3. 337MURAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 23,400 Btu/h · DuctedTop 10%3.16
  4. 4NS18H24HA5***with ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons · 22,400 Btu/h · DuctedTop 10%3.13
  5. 537MUHAQ24AA3with indoor coil D(A,C,E)37A3J+TDR and furnace 59SP6B120V24**22Carrier2 tons · 22,000 Btu/h · DuctedTop 10%3.06
  6. 6AOUK024SSAN7Fujitsu2 tons · 24,000 Btu/h · DuctlessTop 10%3.03
  7. 7KUSXB301Awith ducted air handler D(A,C,E)31D3D+TDRLG2 tons · 26,000 Btu/h · DuctedTop 10%3.00
  8. 8D5CUHAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
  9. 9D5CURAH24AAKwith ducted air handler D(A,C,E)36A3J+TDRCarrier (sold as Tempstar)2 tons · 23,800 Btu/h · DuctedTop 10%2.88
  10. 10TZP15AY24AJ2Nwith ducted air handler L(E,F)W30BJTHERMAL ZONE2 tons · 21,800 Btu/h · DuctedTop 10%2.88

722 ducted, 2 tons models meet it. See them all in the advanced list

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Brands with the most models that meet itShare of each brand’s own models; the dark line is the share across all models.

All models: 53%

Next steps

Advanced view: full criteria table, where each threshold falls across all models, pass rates by duct type, complete model list.

Open the advanced view