- Insights
- Rebate standards
- Xcel CC
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Xcel CC: which heat pumps meet it?
The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate. 53% of certified models (6,515, about 5 in 10) meet it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
What it asks for
Ducted units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 15.2 or more
- Hot-day cooling efficiency (EER2): 10 or more
Ductless units
- Efficiency on a 5°F day (COP at 5°F): 1.75 or more
- Heating power kept at 5°F (Capacity at 5°F vs 47°F): 70% or more of its 47°F output
- Summer-long cooling efficiency (SEER2): 16 or more
- Hot-day cooling efficiency (EER2): 9 or more
A model counts when at least one of its certified pairings meets every line on its own. Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.
- Up to 1.5 tons2,905 of 4,715 models62%
- 2 tons1,062 of 1,748 models61%
- 2.5–3 tons1,369 of 2,724 models50%
- 3.5–4.5 tons1,130 of 2,687 models42%
- 5 tons and up49 of 458 models11%
All sizes: 53%
Source: AHRI directory.
Models that meet it, one size class at a time
Showing Ducted, 2.5–3 tons (27,000–38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
- 1NS21H36MA5-**Awith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances (sold as GE)2.5 tons · 31,400 Btu/h · DuctedTop 10%4.00
- 25A6H5036A1with indoor coil DH36T4J and furnace S9V2C100U5PSCTrane (sold as American Standard)3 tons · 33,600 Btu/h · DuctedTop 10%3.19
- 3KUSXA422Awith ducted air handler D(A,C,E)42B4D+TDRLG3 tons · 37,600 Btu/h · DuctedTop 10%3.16
- 4KUSXB421Awith ducted air handler D(A,C,E)48D3D+TDRLG3 tons · 38,500 Btu/h · DuctedTop 10%3.11
- 5HH836E2S12with indoor coil D(A,C,E)37E3K+TDR and furnace Z8ET100C20LMPS1York (sold as Coleman)2.5 tons · 32,000 Btu/h · DuctedTop 10%3.10
- 65TWR5036A1with indoor coil DH60T4J and furnace S8V2B080M4PCBTrane3 tons · 33,200 Btu/h · DuctedTop 10%3.08
- 7HH836E2S11with indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1York3 tons · 33,200 Btu/h · DuctedTop 10%3.08
- 8RP15AY42AJ2Nwith ducted air handler AE*L+CM59A4J+TDRRheem (sold as RUUD)3 tons · 37,600 Btu/h · DuctedTop 10%3.06
- 95TWX5036A1with indoor coil DH36T4J and furnace S9X1D120U5PSBTrane2.5 tons · 32,000 Btu/h · DuctedTop 10%3.03
- 10A5HP5036A1with indoor coil D(A,C,E)36C3J+TDR and furnace A801X080CM5SDTrane (sold as Runtru)2.5 tons · 31,200 Btu/h · DuctedTop 10%3.00
1,104 ducted, 2.5–3 tons models meet it. See them all in the advanced list
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Want the full criteria table, where each threshold falls on every model, pass rates by duct type and the complete list? Switch to Advanced.
Open the advanced view