Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
COVAC heat pumps: how do their ratings compare?
A typical COVAC heat pump beats 35% of similar heat pumps (same size and type), which is well below average. COVAC has 3 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
35%
of similar heat pumps beaten by its typical model
Well below averageCOVAC has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 3 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 47%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 13%
- Winter-long heating efficiencyHSPF2Beats 28%
- Summer-long cooling efficiencySEER2Beats 46%
- Hot-day cooling efficiencyEER2Beats 36%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want COVAC’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
67%
meet CEE 2025 Tier 1, the level many utility rebates use.
2 models. All brands: 57%.
33%
meet Xcel Energy Colorado’s cold-climate rebate levels.
1 model. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 3%.
COVAC all-around best, by size
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
3 of COVAC’s 3 models of this size and type have all five ratings.
- 1COV-S5-09R454-Owith ductless indoor unit COV-S5-09R454-ICOVAC1 ton · 9,000 Btu/h · DuctlessCold-climate pick, score 34.7Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.95 (COP at 5°F)
- Good
- Winter efficiency
- 9.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.5 (SEER2)
- Good
- Hot-day cooling
- 12.5 (EER2)
- Good
- 2COV-S5-18R454-Owith ductless indoor unit COV-S5-18R454-ICOVAC1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
- Heat kept at 5°F
- 61% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Good
- Winter efficiency
- 9.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 20.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Below the middle
- 3COV-S5-12R454-Owith ductless indoor unit COV-S5-12R454-ICOVAC1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 58% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 58% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.3 (SEER2)
- Below the middle
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has COVAC’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view