Both views use the same certified data. This device remembers your choice.
Generallux heat pumps: how do their ratings compare?
A typical Generallux heat pump beats 49% of similar heat pumps (same size and type), which is about average. Generallux has 17 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
49%
of similar heat pumps beaten by its typical model
About averageGenerallux has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 20 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 40%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 43%
- Winter-long heating efficiencyHSPF2Beats 59%
- Summer-long cooling efficiencySEER2Beats 60%
- Hot-day cooling efficiencyEER2Beats 41%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
77%
meet CEE 2025 Tier 1, the level many utility rebates use.
13 models. All brands: 57%.
71%
meet Xcel Energy Colorado’s cold-climate rebate levels.
12 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models. All brands: 3%.
Generallux all-around best, by size
Showing Ductless, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
3 of Generallux’s 3 models of this size and type have all five ratings.
- 1TSHG24E2S20NAR45Owith ductless indoor unit TSCAS24CD2VIR45IGenerallux2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 60.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.4 (HSPF2)
- Great
- Cooling efficiency
- 22.5 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 2THH24E2S23NAR454Owith ductless indoor unit THH24E2S23NAR454IGenerallux2 tons · 24,000 Btu/h · DuctlessCold-climate pick, score 59.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 22.5 (SEER2)
- Good
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3TAC24CHSAG2R32O18with ductless indoor unit TAC24CHSAG2R32I18Generallux2 tons · 23,000 Btu/h · DuctlessNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 54% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.5 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
Advanced view: Generallux’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.
Open the advanced view