Skip to content

HAIER heat pumps: how do their ratings compare?

A typical HAIER heat pump beats 50% of similar heat pumps (same size and type), which is about average. HAIER has 38 heat pump models in this list.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Overall score

50%

of similar heat pumps beaten by its typical model

About average

HAIER has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 58 models with every rating.

HAIER, rating by ratingStrongest on winter-long heating efficiency (beats 68%), weakest on efficiency on a 5°f day (beats 30%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 30%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 61%
  • Winter-long heating efficiencyHSPF2Beats 68%
  • Summer-long cooling efficiencySEER2Beats 53%
  • Hot-day cooling efficiencyEER2Beats 41%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Want HAIER’s ranks and its models inside every size class? Switch to Advanced

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 95%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    36 models. All brands: 57%.

    See them

  • 82%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    31 models. All brands: 53%.

    See them

  • 0%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    None of its models yet. All brands: 3%.

Top HAIER cold-climate picks, by size

Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.

5 of HAIER’s 6 models of this size and type qualify.

  1. 11U24T3PS*HEwith ducted air handler NAM24V1TA5HAIER2 tons · 24,000 Btu/h · DuctedKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    64.7score / 100
  2. 21Q24RT2BE**with ducted air handler US24MB2BEHAIER2 tons · 24,000 Btu/h · DuctedKeeps 88% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    88% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    10.5 (HSPF2)
    Top 10%
    63.6score / 100
  3. 33Q24RT2BE**HAIER2 tons · 24,000 Btu/h · DuctedKeeps 85% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    59.4score / 100
  4. 41Q24FF2BE**with ducted air handler US24MB2BEHAIER2 tons · 24,000 Btu/h · DuctedKeeps 81% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    9.4 (HSPF2)
    Good
    49.8score / 100
  5. 5QS15H24HA5***with ducted air handler NAM24E1TA5HAIER2 tons · 24,200 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets ENERGY STAR CC
    Heat kept at 5°F
    75% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    8.9 (HSPF2)
    Good
    45.7score / 100

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

The advanced view has HAIER’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.

Open the advanced view