Skip to content

Innova heat pumps: how do their ratings compare?

A typical Innova heat pump beats 32% of similar heat pumps (same size and type), which is well below average. Innova has 332 heat pump models in this list.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Overall score

32%

of similar heat pumps beaten by its typical model

Well below average

Innova has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 332 models with every rating.

Innova, rating by ratingStrongest on heating power kept at 5°f (beats 50%), weakest on efficiency on a 5°f day (beats 22%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 22%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 50%
  • Winter-long heating efficiencyHSPF2Beats 41%
  • Summer-long cooling efficiencySEER2Beats 22%
  • Hot-day cooling efficiencyEER2Beats 29%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Want Innova’s ranks and its models inside every size class? Switch to Advanced

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 0%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    0 models. All brands: 57%.

    See them

  • 32%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    106 models. All brands: 53%.

    See them

  • 0%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    None of its models yet. All brands: 3%.

Innova all-around best, by size

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

277 of Innova’s 277 models of this size and type have all five ratings.

  1. 1AVP19R4H1InnovaAlso listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more1 ton · 11,600 Btu/h · DuctedCold-climate pick, score 57.0Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.95 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    15.4 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    54.1score / 100Heating 57 · Cooling 51
  2. 2AVK09R3H2InnovaAlso listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more0.5 tons · 7,500 Btu/h · DuctedCold-climate pick, score 60.8Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    95% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.9 (HSPF2)
    Good
    Cooling efficiency
    15.4 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    52.7score / 100Heating 61 · Cooling 45
  3. 3ADP09R4H1InnovaAlso listed as ADP09N4H1, ADP09R3H1, ADP09N3H1, ADP09R4H2 and 31 more0.5 tons · 6,100 Btu/h · DuctedCold-climate pick, score 51.6Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    15.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    45.7score / 100Heating 52 · Cooling 40
  4. 4ACK09R3H1InnovaAlso listed as ACK09R3H2, ACK09N3H1, ACK09N3H2, ACU09R3H1 and 7 more0.5 tons · 6,100 Btu/h · DuctedCold-climate pick, score 36.8Meets Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    72% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    15.3 (SEER2)
    Below the middle
    Hot-day cooling
    11.6 (EER2)
    Below the middle
    38.3score / 100Heating 37 · Cooling 40
  5. 5AVP20R3H1-2InnovaAlso listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 more1.5 tons · 20,200 Btu/h · DuctedNot a cold-climate pick: keeps 47% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    48% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.01 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Below the middle
    Cooling efficiency
    13.9 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    36.2score / 100Heating 39 · Cooling 33

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

The advanced view has Innova’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.

Open the advanced view