Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ISLANDAIRE heat pumps: how do their ratings compare?
A typical ISLANDAIRE heat pump beats 17% of similar heat pumps (same size and type), which is well below average. ISLANDAIRE has 15 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
17%
of similar heat pumps beaten by its typical model
Well below averageISLANDAIRE has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 15 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 22%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 17%
- Winter-long heating efficiencyHSPF2Beats 5%
- Summer-long cooling efficiencySEER2Beats 19%
- Hot-day cooling efficiencyEER2Beats 20%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want ISLANDAIRE’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
0%
meet CEE 2025 Tier 1, the level many utility rebates use.
0 models. All brands: 57%.
0%
meet Xcel Energy Colorado’s cold-climate rebate levels.
0 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 3%.
Top ISLANDAIRE cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
3 of ISLANDAIRE’s 14 models of this size and type qualify.
- 1EZMB10L9A1S95AAISLANDAIRE1 ton · 10,000 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Seasonal efficiency
- 7.5 (HSPF2)
- Below the middle
- 2EZMB10L5A1S95AAISLANDAIRE1 ton · 10,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 7.5 (HSPF2)
- Below the middle
- 3EZVV09L**1N*7A*ISLANDAIRE1 ton · 9,600 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.61 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 6.6 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has ISLANDAIRE’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view