Both views use the same certified data. This device remembers your choice.
Kepler heat pumps: how do their ratings compare?
A typical Kepler heat pump beats 63% of similar heat pumps (same size and type), which is well above average. Kepler has 45 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
63%
of similar heat pumps beaten by its typical model
Well above averageKepler has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 66 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 59%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 63%
- Winter-long heating efficiencyHSPF2Beats 74%
- Summer-long cooling efficiencySEER2Beats 65%
- Hot-day cooling efficiencyEER2Beats 58%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
87%
meet CEE 2025 Tier 1, the level many utility rebates use.
39 models. All brands: 57%.
80%
meet Xcel Energy Colorado’s cold-climate rebate levels.
36 models. All brands: 53%.
2%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
1 model. All brands: 3%.
Kepler all-around best, by size
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
10 of Kepler’s 10 models of this size and type have all five ratings.
- 1ODUM6OE30-48HFN10-M1D-DKepler4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2ODUM6OE31-48HFN10-M1XD-DKepler4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 3ODUM6OE31-53HFN10-M1XD-DKepler4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 4ODUMOE30-48HFN10-M2Xwith ducted air handler IDUMTJ-48HWFN10-M2-DKepler4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 16.7 (SEER2)
- Good
- Hot-day cooling
- 10.4 (EER2)
- Below the middle
- 5ODUMOE30-60HFN10-M2Xwith ducted air handler IDUMHJ-60HWFN10-M2-DKepler4.5 tons · 55,000 Btu/h · DuctedCold-climate pick, score 80.4Meets Xcel CC
- Heat kept at 5°F
- 89% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.4 (HSPF2)
- Top 10%
- Cooling efficiency
- 15.8 (SEER2)
- Below the middle
- Hot-day cooling
- 10.2 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
Advanced view: Kepler’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.
Open the advanced view