Skip to content

Panasonic heat pumps: how do their ratings compare?

A typical Panasonic heat pump beats 68% of similar heat pumps (same size and type), which is well above average. Panasonic has 29 heat pump models in this list.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Overall score

68%

of similar heat pumps beaten by its typical model

Well above average

Panasonic has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 37 models with every rating.

Panasonic, rating by ratingStrongest on winter-long heating efficiency (beats 79%), weakest on hot-day cooling efficiency (beats 62%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 69%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 66%
  • Winter-long heating efficiencyHSPF2Beats 79%
  • Summer-long cooling efficiencySEER2Beats 70%
  • Hot-day cooling efficiencyEER2Beats 62%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 97%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    28 models. All brands: 57%.

    See them

  • 90%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    26 models. All brands: 53%.

    See them

  • 21%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    6 models. All brands: 3%.

    See them

Top Panasonic cold-climate picks, by size

3 of Panasonic’s 3 models of this size and type qualify.

  1. 1CU-YM24CBUCwith ducted air handler CS-YM24CD1UWPanasonic2 tons · 24,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    76% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Seasonal efficiency
    11.0 (HSPF2)
    Top 10%
    77.1score / 100
  2. 2CU-HM24BAHUwith ducted air handler CS-HM24BAHUPanasonic2 tons · 23,000 Btu/h · DuctedKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.87 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    66.3score / 100
  3. 3CU-M24BAHUwith ducted air handler CS-HM24BAHUPanasonic2 tons · 24,000 Btu/h · DuctedKeeps 83% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.87 (COP at 5°F)
    Below the middle
    Seasonal efficiency
    9.7 (HSPF2)
    Great
    59.6score / 100

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

Advanced view: Panasonic’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter