Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Proair heat pumps: how do their ratings compare?
A typical Proair heat pump beats 52% of similar heat pumps (same size and type), which is about average. Proair has 30 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
52%
of similar heat pumps beaten by its typical model
About averageProair has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 40 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 49%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 55%
- Winter-long heating efficiencyHSPF2Beats 59%
- Summer-long cooling efficiencySEER2Beats 55%
- Hot-day cooling efficiencyEER2Beats 44%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want Proair’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
70%
meet CEE 2025 Tier 1, the level many utility rebates use.
21 models. All brands: 57%.
67%
meet Xcel Energy Colorado’s cold-climate rebate levels.
20 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 3%.
Top Proair cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
4 of Proair’s 7 models of this size and type qualify.
- 1PMUL-H3P-18HP-MProair1.5 tons · 19,000 Btu/h · DuctlessKeeps 90% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
- 2PMUL-A3P-18HP-MProair1.5 tons · 18,000 Btu/h · DuctlessKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
- 3POX21-09HFN10-Mwith ductless indoor unit PSAG-09HWM-MProair1 ton · 9,000 Btu/h · DuctlessKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.4 (HSPF2)
- Below the middle
- 4POX21-09HFN10-115with ductless indoor unit PSAG-09HWM-M-115Proair1 ton · 9,000 Btu/h · DuctlessKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.95 (COP at 5°F)
- Good
- Seasonal efficiency
- 9.0 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has Proair’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view