Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TCL heat pumps: how do their ratings compare?
A typical TCL heat pump beats 49% of similar heat pumps (same size and type), which is about average. TCL has 177 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
49%
of similar heat pumps beaten by its typical model
About averageTCL has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 198 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 36%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 50%
- Winter-long heating efficiencyHSPF2Beats 52%
- Summer-long cooling efficiencySEER2Beats 59%
- Hot-day cooling efficiencyEER2Beats 41%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want TCL’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
76%
meet CEE 2025 Tier 1, the level many utility rebates use.
134 models. All brands: 57%.
72%
meet Xcel Energy Colorado’s cold-climate rebate levels.
128 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 3%.
TCL all-around best, by size
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
22 of TCL’s 22 models of this size and type have all five ratings.
- 1TMH42HEI2NAM0U24TCLAlso listed as H42FMH20XPC3.5 tons · 41,000 Btu/h · DuctedCold-climate pick, score 52.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2TMH42HDI2NAO0U25TCLAlso listed as TMH42HDI2NAO0U253.5 tons · 39,000 Btu/h · DuctedCold-climate pick, score 63.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 3H48SDH20XQCwith ducted air handler H48APH20UDETCLAlso listed as THH48HDI2NAJ0H264 tons · 48,000 Btu/h · DuctedCold-climate pick, score 69.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 4TMH48HEI2NAS0U25*TCLAlso listed as H48FMHD6XPC4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 53.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.75 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 5H60SDH20XQCwith ducted air handler H60APH20UDETCLAlso listed as THH55HDI2NAJ0H264.5 tons · 54,000 Btu/h · DuctedCold-climate pick, score 66.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 93% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 10.0 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has TCL’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.