Both views use the same certified data. This device remembers your choice.
WHIRLPOOL heat pumps: how do their ratings compare?
A typical WHIRLPOOL heat pump beats 26% of similar heat pumps (same size and type), which is well below average. WHIRLPOOL has 59 heat pump models in this list.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Overall score
26%
of similar heat pumps beaten by its typical model
Well below averageWHIRLPOOL has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 42 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 41%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 21%
- Winter-long heating efficiencyHSPF2Beats 22%
- Summer-long cooling efficiencySEER2Beats 19%
- Hot-day cooling efficiencyEER2Beats 33%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Rebate standards
2%
meet CEE 2025 Tier 1, the level many utility rebates use.
1 model. All brands: 57%.
3%
meet Xcel Energy Colorado’s cold-climate rebate levels.
2 models. All brands: 53%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models. All brands: 3%.
WHIRLPOOL all-around best, by size
Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
12 of WHIRLPOOL’s 16 models of this size and type have all five ratings.
- 1WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDRWHIRLPOOL2.5 tons · 32,400 Btu/h · DuctedCold-climate pick, score 78.4Meets Xcel CC
- Heat kept at 5°F
- 127% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.73 (COP at 5°F)
- Top 10%
- Winter efficiency
- 7.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 2WLP14AY36AJ2Nwith ducted air handler WLH2TY3621STANNWHIRLPOOL3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 65% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 52% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 3WLP14AY30AJ2Nwith ducted air handler WLB2TY3621STANMWHIRLPOOL2.5 tons · 28,400 Btu/h · DuctedNot a cold-climate pick: keeps 58% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 46% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Good
- 4RHPBYC036AJTWHIRLPOOL3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 40% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 41% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.82 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.2 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.5 (EER2)
- Good
- 5RHPCYB036ACWHIRLPOOLAlso listed as RHPCYB036AD, RHPCYB036AJ3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 47% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 47% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.99 (COP at 5°F)
- Below the middle
- Winter efficiency
- 6.7 (HSPF2)
- Below the middle
- Cooling efficiency
- 13.4 (SEER2)
- Below the middle
- Hot-day cooling
- 10.6 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
Advanced view: WHIRLPOOL’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.
Open the advanced view