Skip to content

WHIRLPOOL heat pump efficiency: 59 outdoor models compared

WHIRLPOOL has 59 heat pump outdoor models certified with this refrigerant group, in 368 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes WHIRLPOOL makes. WHIRLPOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
59
AHRI certifications
368
Efficiency index
26%
Typical model vs same-size, same-type peers (42 models)
Meet CEE 2025
1.7%
1 model

How WHIRLPOOL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
WHIRLPOOL against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of WHIRLPOOL’s own modelsWHIRLPOOL is strongest on COP at 5°F (its typical model beats 41% of comparable models) and weakest on SEER2 (19%).
  • WHIRLPOOL
  • Middle half of its models
  • Other ranked manufacturers
WHIRLPOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile of WHIRLPOOL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index42 models scored26%Not ranked—
COP at 5°F42 models scored41%Not ranked1.87
Capacity retention at 5°F42 models scored21%Not ranked47%
HSPF259 models scored22%Not ranked7.5
SEER259 models scored19%Not ranked14.3
EER259 models scored33%Not ranked10.6
Heating capacity at 5°F42 models scored22%Not ranked19,550 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
WHIRLPOOL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • WHIRLPOOL (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons226%44%18%29%
Ducted, 2 tons725%46%17%17%
Ducted, 2.5 to 3 tons1624%45%18%15%
Ducted, 3.5 to 4.5 tons2528%41%23%21%
Ducted, 5 tons and up926%31%28%18%

Every WHIRLPOOL model in the market

WHIRLPOOL’s 59 models with a known size and duct type, over the shape of the whole catalog.
WHIRLPOOL models by size and ratingColoured: WHIRLPOOL · grey shapes: all 15,936 models · lines: catalog medians by size
  • WHIRLPOOL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 59 whirlpool models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top WHIRLPOOL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 2 WHIRLPOOL cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1WLP15AY36AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR2.5 tons32,400 Btu/h · Ducted127%2.737.840,50015.2Xcel30218687485Ducted, 2.5 to 3 tons78.4
2WLP15AY30AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR2 tons26,800 Btu/h · Ducted127%2.727.834,60015.2Xcel27218687483Ducted, 2 tons75.4

All-around best

Top 5 WHIRLPOOL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1WLP15AY36AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR2.5 tons32,400 Btu/h · Ducted127%2.737.815.211.7Xcel30218687485Ducted, 2.5 to 3 tons63.578.448.678.4
2WLP15AY60AJ2NWHIRLPOOL · CLASSICwith ducted air handler WLH2TY6024STANN5 tons57,000 Btu/h · Ducted50%2.107.815.211.7None21217536707Ducted, 5 tons and up57.056.058.1Not a pick
3WLP15AY30AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR2 tons26,800 Btu/h · Ducted127%2.727.815.211.7Xcel27218687483Ducted, 2 tons56.675.437.875.4
4WLP15AY42AJ2NWHIRLPOOL · WHIRLPOOLwith ducted air handler WLH2TY4824STANN3.5 tons40,000 Btu/h · Ducted46%2.108.116.011.7CEE 2523217619601Ducted, 3.5 to 4.5 tons54.744.964.6Not a pick
5WLP15AY48AJ2NWHIRLPOOL · WHIRLPOOLwith ducted air handler WLH2TY4824STANN4 tons45,500 Btu/h · Ducted51%2.208.115.211.7None23217619600Ducted, 3.5 to 4.5 tons54.550.958.1Not a pick

Best model on each rating

WHIRLPOOL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FWLP15AY36AJ2N2.73Ducted, 2.5 to 3 tons98%218687485
Capacity retention at 5°FWLP15AY30AJ2N127%Ducted, 2 tons100%218687483
HSPF2WLP15AY60AJ2N7.8Ducted, 5 tons and up56%217536707
SEER2WLP15AY42AJ2N16.0Ducted, 3.5 to 4.5 tons49%217619601
EER2WLP15AY48AJ2N11.7Ducted, 3.5 to 4.5 tons69%217536705
Heating capacity at 5°FWLP15AY30AJ2N34,600 Btu/hDucted, 2 tons100%218687483

All 59 WHIRLPOOL models in Explore

WHIRLPOOL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
WHIRLPOOL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)35.8(50 is the typical model of its size class)WLP15AY18AJ2Nwith ducted air handler WLH2TY2417STANN2 of 2 models have all five ratings · AHRI 217536709
Ducted, 2 tons75.4(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 7 models qualify · AHRI 21868748356.6(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR6 of 6 models have all five ratings · AHRI 218687483
Ducted, 2.5 to 3 tons78.4(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 16 models qualify · AHRI 21868748563.5(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR12 of 16 models have all five ratings · AHRI 218687485
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 25 models qualify)54.7(50 is the typical model of its size class)WLP15AY42AJ2Nwith ducted air handler WLH2TY4824STANN14 of 25 models have all five ratings · AHRI 217619601
Ducted, 5 tons and upNone on this board (0 of 9 models qualify)57.0(50 is the typical model of its size class)WLP15AY60AJ2Nwith ducted air handler WLH2TY6024STANN8 of 10 models have all five ratings · AHRI 217536707

All-around board, every manufacturer

Newest WHIRLPOOL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified WHIRLPOOL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
WLP15AY60AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY6021STAAM and furnace WL962V0705A21M4S4.5 tons54,000 Btu/h · Ducted1.9050%7.714.3None21218833362
WLP15AY48AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY4824STANM and furnace WL962V0705A21M4S4 tons45,500 Btu/h · Ducted2.1053%8.115.2None23218833355
WLP15AY42AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY4824STANM and furnace WL962V0705A21M4S3.5 tons40,000 Btu/h · Ducted2.0048%8.116.0CEE 2523218833353
WLP15AY30AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY3621STANM and furnace WL962V0603A17M4S2.5 tons28,400 Btu/h · Ducted1.8049%7.515.0Xcel27218833352
WLP15AY36AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY3621STANM and furnace WL962V0855A21M4S3 tons34,200 Btu/h · Ducted2.0054%7.815.2Xcel30218833341

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for WHIRLPOOL in this group.

Compare WHIRLPOOL

Manufacturers of a similar size, side by side.

WHIRLPOOL includes these brand names as listed in AHRI: WHIRLPOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter