- Insights
- Manufacturers
- WHIRLPOOL
Both views use the same certified data. This device remembers your choice.
WHIRLPOOL heat pump efficiency: 59 outdoor models compared
WHIRLPOOL has 59 heat pump outdoor models certified with this refrigerant group, in 368 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes WHIRLPOOL makes. WHIRLPOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 59
- AHRI certifications
- 368
- Efficiency index
- 26%
- Typical model vs same-size, same-type peers (42 models)
- Meet CEE 2025
- 1.7%
- 1 model
How WHIRLPOOL compares with comparable models
- WHIRLPOOL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index42 models scored | 26% | Not ranked | — |
| COP at 5°F42 models scored | 41% | Not ranked | 1.87 |
| Capacity retention at 5°F42 models scored | 21% | Not ranked | 47% |
| HSPF259 models scored | 22% | Not ranked | 7.5 |
| SEER259 models scored | 19% | Not ranked | 14.3 |
| EER259 models scored | 33% | Not ranked | 10.6 |
| Heating capacity at 5°F42 models scored | 22% | Not ranked | 19,550 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 1.7% | 1 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 3.4% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- WHIRLPOOL (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 26% | 44% | 18% | 29% |
| Ducted, 2 tons | 7 | 25% | 46% | 17% | 17% |
| Ducted, 2.5 to 3 tons | 16 | 24% | 45% | 18% | 15% |
| Ducted, 3.5 to 4.5 tons | 25 | 28% | 41% | 23% | 21% |
| Ducted, 5 tons and up | 9 | 26% | 31% | 28% | 18% |
Every WHIRLPOOL model in the market
- WHIRLPOOL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top WHIRLPOOL models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WLP15AY36AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR | 2.5 tons32,400 Btu/h · Ducted | 127% | 2.73 | 7.8 | 40,500 | 15.2 | Xcel | 30 | 218687485 | Ducted, 2.5 to 3 tons | 78.4 |
| 2WLP15AY30AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR | 2 tons26,800 Btu/h · Ducted | 127% | 2.72 | 7.8 | 34,600 | 15.2 | Xcel | 27 | 218687483 | Ducted, 2 tons | 75.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WLP15AY36AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR | 2.5 tons32,400 Btu/h · Ducted | 127% | 2.73 | 7.8 | 15.2 | 11.7 | Xcel | 30 | 218687485 | Ducted, 2.5 to 3 tons | 63.5 | 78.4 | 48.6 | 78.4 |
| 2WLP15AY60AJ2NWHIRLPOOL · CLASSICwith ducted air handler WLH2TY6024STANN | 5 tons57,000 Btu/h · Ducted | 50% | 2.10 | 7.8 | 15.2 | 11.7 | None | 21 | 217536707 | Ducted, 5 tons and up | 57.0 | 56.0 | 58.1 | Not a pick |
| 3WLP15AY30AJ2NWHIRLPOOLwith ducted air handler AE*S+DM36A3J+TDR | 2 tons26,800 Btu/h · Ducted | 127% | 2.72 | 7.8 | 15.2 | 11.7 | Xcel | 27 | 218687483 | Ducted, 2 tons | 56.6 | 75.4 | 37.8 | 75.4 |
| 4WLP15AY42AJ2NWHIRLPOOL · WHIRLPOOLwith ducted air handler WLH2TY4824STANN | 3.5 tons40,000 Btu/h · Ducted | 46% | 2.10 | 8.1 | 16.0 | 11.7 | CEE 25 | 23 | 217619601 | Ducted, 3.5 to 4.5 tons | 54.7 | 44.9 | 64.6 | Not a pick |
| 5WLP15AY48AJ2NWHIRLPOOL · WHIRLPOOLwith ducted air handler WLH2TY4824STANN | 4 tons45,500 Btu/h · Ducted | 51% | 2.20 | 8.1 | 15.2 | 11.7 | None | 23 | 217619600 | Ducted, 3.5 to 4.5 tons | 54.5 | 50.9 | 58.1 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WLP15AY36AJ2N | 2.73 | Ducted, 2.5 to 3 tons | 98% | 218687485 |
| Capacity retention at 5°F | WLP15AY30AJ2N | 127% | Ducted, 2 tons | 100% | 218687483 |
| HSPF2 | WLP15AY60AJ2N | 7.8 | Ducted, 5 tons and up | 56% | 217536707 |
| SEER2 | WLP15AY42AJ2N | 16.0 | Ducted, 3.5 to 4.5 tons | 49% | 217619601 |
| EER2 | WLP15AY48AJ2N | 11.7 | Ducted, 3.5 to 4.5 tons | 69% | 217536705 |
| Heating capacity at 5°F | WLP15AY30AJ2N | 34,600 Btu/h | Ducted, 2 tons | 100% | 218687483 |
WHIRLPOOL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | 35.8(50 is the typical model of its size class)WLP15AY18AJ2Nwith ducted air handler WLH2TY2417STANN2 of 2 models have all five ratings · AHRI 217536709 |
| Ducted, 2 tons | 75.4(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 7 models qualify · AHRI 218687483 | 56.6(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR6 of 6 models have all five ratings · AHRI 218687483 |
| Ducted, 2.5 to 3 tons | 78.4(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 16 models qualify · AHRI 218687485 | 63.5(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR12 of 16 models have all five ratings · AHRI 218687485 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 25 models qualify) | 54.7(50 is the typical model of its size class)WLP15AY42AJ2Nwith ducted air handler WLH2TY4824STANN14 of 25 models have all five ratings · AHRI 217619601 |
| Ducted, 5 tons and up | None on this board (0 of 9 models qualify) | 57.0(50 is the typical model of its size class)WLP15AY60AJ2Nwith ducted air handler WLH2TY6024STANN8 of 10 models have all five ratings · AHRI 217536707 |
Newest WHIRLPOOL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WLP15AY60AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY6021STAAM and furnace WL962V0705A21M4S | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 50% | 7.7 | 14.3 | None | 21 | 218833362 |
| WLP15AY48AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY4824STANM and furnace WL962V0705A21M4S | 4 tons45,500 Btu/h · Ducted | 2.10 | 53% | 8.1 | 15.2 | None | 23 | 218833355 |
| WLP15AY42AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY4824STANM and furnace WL962V0705A21M4S | 3.5 tons40,000 Btu/h · Ducted | 2.00 | 48% | 8.1 | 16.0 | CEE 25 | 23 | 218833353 |
| WLP15AY30AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY3621STANM and furnace WL962V0603A17M4S | 2.5 tons28,400 Btu/h · Ducted | 1.80 | 49% | 7.5 | 15.0 | Xcel | 27 | 218833352 |
| WLP15AY36AJ2NWHIRLPOOL · WHIRLPOOLwith indoor coil TCFY3621STANM and furnace WL962V0855A21M4S | 3 tons34,200 Btu/h · Ducted | 2.00 | 54% | 7.8 | 15.2 | Xcel | 30 | 218833341 |
Compare WHIRLPOOL
WHIRLPOOL includes these brand names as listed in AHRI: WHIRLPOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.