Skip to content

iCongo vs WHIRLPOOL heat pumps

Measured against models of the same size and duct type, iCongo scores higher on 4 of the 6 ratings. iCongo has 59 outdoor models, WHIRLPOOL has 59 outdoor models. iCongo and WHIRLPOOL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
iCongo and WHIRLPOOL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, iCongo scores higher on 4 of the 6 ratings.
  • iCongo
  • WHIRLPOOL
  • Other ranked manufacturers
iCongoWHIRLPOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingiCongoWHIRLPOOL
Efficiency index36% (higher)median —26% (higher)median —
COP at 5°F30%median 1.8041%median 1.87
Capacity retention at 5°F45% (higher)median 64%21% (higher)median 47%
HSPF239% (higher)median 8.022% (higher)median 7.5
SEER241% (higher)median 15.219% (higher)median 14.3
EER225%median 10.033%median 10.6
Heating capacity at 5°F48% (higher)median 22,000 Btu/h22% (higher)median 19,550 Btu/h
Outdoor models5959
AHRI certifications167368

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardiCongoWHIRLPOOL
CEE 2025 Tier 1 (Split ASHP)25.4%15 models1.7%1 models
CEE 2026 Tier 1 (Split ASHP)25.4%15 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)27.1%16 models3.4%2 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • iCongo
  • WHIRLPOOL
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeiCongoWHIRLPOOL
Ducted, up to 1.5 tons11 · index 18%2 · index 26%
Ducted, 2 tons12 · index 37%7 · index 25%
Ducted, 2.5 to 3 tons14 · index 32%16 · index 24%
Ducted, 3.5 to 4.5 tons22 · index 46%25 · index 28%
Ducted, 5 tons and upNone9 · index 26%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeiCongoCold-climate score, best modelWHIRLPOOLCold-climate score, best model
Ducted, up to 1.5 tons46.7(50 is the typical model of its size class)ZOC-18HIN4-M-SE18with ducted air handler ZVMQFA-18HIN4L-M-SE154 of 11 models qualify · AHRI 217902692None on this board (0 of 2 models qualify)
Ducted, 2 tons70.1(50 is the typical model of its size class)ZWDA-24HI1N4-M-SE18Also listed as ZWDA-24HI1N4-M-SE189 of 12 models qualify · AHRI 21702253375.4(50 is the typical model of its size class) (higher)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 7 models qualify · AHRI 218687483
Ducted, 2.5 to 3 tons68.9(50 is the typical model of its size class)ZOD-36HIN4-M-SE18Hwith ducted air handler ZVMXFB-36HI1N4-C-M-SE183 of 14 models qualify · AHRI 21864796778.4(50 is the typical model of its size class) (higher)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 16 models qualify · AHRI 218687485
Ducted, 3.5 to 4.5 tons66.2(50 is the typical model of its size class)ZODA-48HIN4-M-SE18H*with ducted air handler ZVMXFC-48HI1N4-C-M-SE1811 of 22 models qualify · AHRI 218673039None on this board (0 of 25 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 9 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeiCongoAll-around score, best modelWHIRLPOOLAll-around score, best model
Ducted, up to 1.5 tons40.5(50 is the typical model of its size class) (higher)ZOC-18HIN4-M-SE18with ducted air handler ZVMXFA-18HI1N4-C-M-SE1811 of 11 models have all five ratings · AHRI 21702253735.8(50 is the typical model of its size class)WLP15AY18AJ2Nwith ducted air handler WLH2TY2417STANN2 of 2 models have all five ratings · AHRI 217536709
Ducted, 2 tons77.0(50 is the typical model of its size class) (higher)ZOT6P-24HIN4-M-SE20with ducted air handler ZVMXFB-24HI1N4-M-SE2012 of 12 models have all five ratings · AHRI 21790268856.6(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR6 of 6 models have all five ratings · AHRI 218687483
Ducted, 2.5 to 3 tons54.3(50 is the typical model of its size class)ZOT6P-36HIN4-M-SE20with ducted air handler ZVMXFB-36HI1N4-M-SE2014 of 14 models have all five ratings · AHRI 21790268963.5(50 is the typical model of its size class) (higher)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR12 of 16 models have all five ratings · AHRI 218687485
Ducted, 3.5 to 4.5 tons66.2(50 is the typical model of its size class) (higher)ZWDB-48HI1N4S4-M-SE1822 of 22 models have all five ratings · AHRI 21846723754.7(50 is the typical model of its size class)WLP15AY42AJ2Nwith ducted air handler WLH2TY4824STANN14 of 25 models have all five ratings · AHRI 217619601
Ducted, 5 tons and upNo models in this size class57.0(50 is the typical model of its size class)WLP15AY60AJ2Nwith ducted air handler WLH2TY6024STANN8 of 10 models have all five ratings · AHRI 217536707

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingiCongoWHIRLPOOL
COP at 5°Fbeats 98% · 2.80ZOT6PA-42HN4-M-SE14.3Ducted, 3.5 to 4.5 tonsbeats 98% · 2.73WLP15AY36AJ2NDucted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 99% · 115%ZOD-36HIN4-M-SE18HDucted, 2.5 to 3 tonsbeats 100% · 127%WLP15AY30AJ2NDucted, 2 tons
HSPF2beats 87% · 10.1ZOD-36HIN4-M-SE18HDucted, 2.5 to 3 tonsbeats 56% · 7.8WLP15AY60AJ2NDucted, 5 tons and up
SEER2beats 86% · 19.3ZOT6P-36HIN4-M-SE20Ducted, 2.5 to 3 tonsbeats 49% · 16.0WLP15AY42AJ2NDucted, 3.5 to 4.5 tons
EER2beats 82% · 12.5ZOT6P-24HIN4-M-SE20Ducted, 2 tonsbeats 69% · 11.7WLP15AY48AJ2NDucted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 100% · 42,500 Btu/hZOD-36HIN4-M-SE18HDucted, 2.5 to 3 tonsbeats 100% · 34,600 Btu/hWLP15AY30AJ2NDucted, 2 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy