1HVAC vs AireForce: heat pump ratings compared
Against heat pumps of the same size and type, a typical 1HVAC model beats 62% and a typical AireForce model 39%. 1HVAC rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
1HVAC
62%
of similar heat pumps beaten by its typical model
Well above average70 models listed
AireForce
39%
of similar heat pumps beaten by its typical model
Well below average70 models listed
- Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 58%AireForce: Beats 32%
- Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 60%AireForce: Beats 41%
- Winter-long heating efficiencyHSPF21HVAC: Beats 71%AireForce: Beats 39%
- Summer-long cooling efficiencySEER21HVAC: Beats 65%AireForce: Beats 42%
- Hot-day cooling efficiencyEER21HVAC: Beats 56%AireForce: Beats 42%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- 1HVAC
- 87%
- AireForce
- 50%
Xcel CC
- 1HVAC
- 74%
- AireForce
- 49%
CEE Advanced
- 1HVAC
- 4%
- AireForce
- 3%
ENERGY STAR CC
- 1HVAC
- 77%
- AireForce
- 17%
Top cold-climate picks, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
1HVAC
- 1ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB1HVAC1.5 tons · 18,000 Btu/h · DuctedKeeps 103% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.8 (HSPF2)
- Top 10%
- 2ACIQ-18ZPL-HP230Cwith ducted air handler ACIQ-18CD-HH-MC1HVAC1.5 tons · 17,500 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.1 (HSPF2)
- Top 10%
- 3ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC1HVAC1 ton · 9,000 Btu/h · DuctedKeeps 120% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 120% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
AireForce
- 1AC-18-HP-E-32with ducted air handler AC-18-AH-E-32AireForce1.5 tons · 18,000 Btu/h · DuctedKeeps 78% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.6 (HSPF2)
- Below the middle
- 2DXH18FMK3IHAireForce1.5 tons · 16,000 Btu/h · DuctedKeeps 76% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 76% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.1 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.