Skip to content

1HVAC vs COSTWAY: heat pump ratings compared

Against heat pumps of the same size and type, a typical 1HVAC model beats 62% and a typical COSTWAY model 48%. 1HVAC rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

1HVAC

62%

of similar heat pumps beaten by its typical model

Well above average

70 models listed

COSTWAY

48%

of similar heat pumps beaten by its typical model

About average

71 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 58%COSTWAY: Beats 50%
  • Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 60%COSTWAY: Beats 40%
  • Winter-long heating efficiencyHSPF21HVAC: Beats 71%COSTWAY: Beats 50%
  • Summer-long cooling efficiencySEER21HVAC: Beats 65%COSTWAY: Beats 53%
  • Hot-day cooling efficiencyEER21HVAC: Beats 56%COSTWAY: Beats 40%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    1HVAC
    87%
    COSTWAY
    72%
  • Xcel CC

    1HVAC
    74%
    COSTWAY
    56%
  • CEE Advanced

    1HVAC
    4%
    COSTWAY
    0%
  • ENERGY STAR CC

    1HVAC
    77%
    COSTWAY
    27%

All-around best, ducted up to 1.5 tons

1HVAC

  1. 1ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC1HVAC1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    120% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    86.9score / 100Heating 80 · Cooling 94
  2. 2ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB1HVAC1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 86.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.8 (HSPF2)
    Top 10%
    Cooling efficiency
    19.3 (SEER2)
    Good
    Hot-day cooling
    12.1 (EER2)
    Great
    80.3score / 100Heating 87 · Cooling 74
  3. 3ACIQ-18Z-HH-M3C1HVAC1.5 tons · 19,000 Btu/h · DuctedCold-climate pick, score 71.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Great
    77.8score / 100Heating 71 · Cooling 84

COSTWAY

  1. 1FP11133USCOSTWAY1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 49.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    84% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    53.1score / 100Heating 49 · Cooling 57

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter