1HVAC vs COSTWAY heat pumps
Measured against models of the same size and duct type, 1HVAC scores higher on 6 of the 6 ratings. 1HVAC has 70 outdoor models, COSTWAY has 71 outdoor models. 1HVAC has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- 1HVAC
- COSTWAY
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | 1HVAC | COSTWAY |
|---|---|---|
| Efficiency index | 62% (higher)median — | 48% (higher)median — · 26th ranked |
| COP at 5°F | 58% (higher)median 2.00 | 50% (higher)median 2.00 · 18th ranked |
| Capacity retention at 5°F | 60% (higher)median 78% | 40% (higher)median 72% · 26th ranked |
| HSPF2 | 71% (higher)median 10.0 | 50% (higher)median 9.5 · 17th ranked |
| SEER2 | 65% (higher)median 19.8 | 53% (higher)median 21.0 · 16th ranked |
| EER2 | 56% (higher)median 11.9 | 40% (higher)median 11.2 · 25th ranked |
| Heating capacity at 5°F | 63% (higher)median 21,000 Btu/h | 42% (higher)median 11,600 Btu/h · 26th ranked |
| Outdoor models | 70 | 71 |
| AHRI certifications | 166 | 75 |
Share of models meeting each standard
| Standard | 1HVAC | COSTWAY |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 87.1%61 models | 71.8%51 models |
| CEE 2026 Tier 1 (Split ASHP) | 85.7%60 models | 71.8%51 models |
| CEE Advanced Tier (Split ASHP) | 4.3%3 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 74.3%52 models | 56.3%40 models |
| DOE Cold Climate Heat Pump Challenge | 4.3%3 models | 0%0 models |
| ENERGY STAR Cold Climate | 77.1%54 models | 26.8%19 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- 1HVAC
- COSTWAY
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | 1HVAC | COSTWAY |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 75% | 1 · index 53% |
| Ducted, 2 tons | 8 · index 64% | 1 · index 37% |
| Ducted, 2.5 to 3 tons | 12 · index 65% | 6 · index 61% |
| Ducted, 3.5 to 4.5 tons | 17 · index 65% | 2 · index 46% |
| Ducted, 5 tons and up | 1 · index 63% | None |
| Non-ducted, up to 1.5 tons | 22 · index 61% | 46 · index 44% |
| Non-ducted, 2 tons | 6 · index 55% | 12 · index 49% |
| Non-ducted, 2.5 to 3 tons | 9 · index 49% | 7 · index 56% |
| Non-ducted, 3.5 to 4.5 tons | 6 · index 53% | None |
| Non-ducted, 5 tons and up | 1 · index 59% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | 1HVACCold-climate score, best model | COSTWAYCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class) (higher)ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB7 of 8 models qualify · AHRI 216980821 | 49.0(50 is the typical model of its size class)FP11133US1 of 1 models qualify · AHRI 218082696 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models qualify · AHRI 216032281 | 42.0(50 is the typical model of its size class)FP11018USwith ducted air handler FP11021US1 of 1 models qualify · AHRI 217169696 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC11 of 12 models qualify · AHRI 216032282 | 64.6(50 is the typical model of its size class)FP10982USwith ducted air handler FP10985US6 of 6 models qualify · AHRI 217221416 |
| Ducted, 3.5 to 4.5 tons | 85.1(50 is the typical model of its size class) (higher)ACIQ-60-HP32with ducted air handler ACIQ-60-AH3217 of 17 models qualify · AHRI 215387237 | 64.7(50 is the typical model of its size class)FP10983USwith ducted air handler FP10986US2 of 2 models qualify · AHRI 217221417 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD14 of 22 models qualify · AHRI 216032267 | 80.7(50 is the typical model of its size class)FP10897US-12WHwith ductless indoor unit FP10897US-22WH25 of 46 models qualify · AHRI 215876635 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24CC-HH-MC4 of 6 models qualify · AHRI 216032275 | 78.3(50 is the typical model of its size class)FP10898US-12WHwith ductless indoor unit FP10898US-22WH3 of 12 models qualify · AHRI 217178697 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD6 of 9 models qualify · AHRI 216032289 | 58.3(50 is the typical model of its size class)FP10840US-WH7 of 7 models qualify · AHRI 216771328 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)ACIQ-48Z-HH-M6C6 of 6 models qualify · AHRI 216032306 | No models in this size class |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | 1HVACAll-around score, best model | COSTWAYAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC8 of 8 models have all five ratings · AHRI 216032278 | 53.1(50 is the typical model of its size class)FP11133US1 of 1 models have all five ratings · AHRI 218082696 |
| Ducted, 2 tons | 78.6(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models have all five ratings · AHRI 216032281 | 37.0(50 is the typical model of its size class)FP11018USwith ducted air handler FP11021US1 of 1 models have all five ratings · AHRI 217169696 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C12 of 12 models have all five ratings · AHRI 216032302 | 67.9(50 is the typical model of its size class)FP10982USwith ducted air handler FP10985US6 of 6 models have all five ratings · AHRI 217221416 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)ES-48Z-M6C17 of 17 models have all five ratings · AHRI 216032320 | 54.4(50 is the typical model of its size class)FP10983USwith ducted air handler FP10986US2 of 2 models have all five ratings · AHRI 217221417 |
| Ducted, 5 tons and up | 63.2(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032323 | No models in this size class |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD22 of 22 models have all five ratings · AHRI 216032267 | 84.3(50 is the typical model of its size class)FP10897US-12WHwith ductless indoor unit FP10897US-22WH41 of 46 models have all five ratings · AHRI 215876635 |
| Non-ducted, 2 tons | 78.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24W-HH-MD6 of 6 models have all five ratings · AHRI 216032271 | 87.2(50 is the typical model of its size class) (higher)FP10898US-12WHwith ductless indoor unit FP10898US-22WH11 of 12 models have all five ratings · AHRI 217178697 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C9 of 9 models have all five ratings · AHRI 216032301 | 67.4(50 is the typical model of its size class)FP10840US-WH7 of 7 models have all five ratings · AHRI 216771328 |
| Non-ducted, 3.5 to 4.5 tons | 75.5(50 is the typical model of its size class)ACIQ-48Z-HH-M6C6 of 6 models have all five ratings · AHRI 216032304 | No models in this size class |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032322 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | 1HVAC | COSTWAY |
|---|---|---|
| COP at 5°F | beats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tons | beats 90% · 2.25FP10897US-12WHNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 98% · 126%ACIQ-09ZPL-HP230CNon-ducted, up to 1.5 tons | beats 81% · 90%FP10841US-WHNon-ducted, 2 tons |
| HSPF2 | beats 99% · 14.8ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tons | beats 96% · 10.5FP11135USAlso listed as FP11135USDucted, 2.5 to 3 tons |
| SEER2 | beats 97% · 25.0ES-27Z-M4CNon-ducted, 2.5 to 3 tons | beats 98% · 21.0FP11134USAlso listed as FP11134USDucted, 2.5 to 3 tons |
| EER2 | beats 99% · 18.0ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tons | beats 97% · 14.0FP10898US-12WHNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 98% · 19,600 Btu/hACIQ-18-HPDDucted, up to 1.5 tons | beats 89% · 16,000 Btu/hFP11133USNon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- 1HVAC (median, middle 50%)
- COSTWAY (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| 1HVAC, 47°F | 69 | 100% | 100% | 100% | 100% | 100% |
| 1HVAC, 17°F | 69 | 65% | 68% | 73% | 79% | 87% |
| 1HVAC, 5°F | 69 | 57% | 60% | 68% | 80% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| 1HVAC, 47°F | 69 | 2.93 | 3.1 | 3.28 | 3.51 | 3.68 |
| 1HVAC, 17°F | 69 | 2.01 | 2.22 | 2.36 | 2.5 | 2.7 |
| 1HVAC, 5°F | 69 | 1.85 | 1.91 | 2 | 2.1 | 2.31 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| COSTWAY, 47°F | 31 | 100% | 100% | 100% | 100% | 100% |
| COSTWAY, 17°F | 31 | 70% | 72% | 73% | 76% | 78% |
| COSTWAY, 5°F | 31 | 59% | 64% | 66% | 70% | 72% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| COSTWAY, 47°F | 31 | 2.47 | 2.95 | 3.3 | 3.51 | 3.66 |
| COSTWAY, 17°F | 31 | 1.91 | 2.1 | 2.2 | 2.25 | 2.4 |
| COSTWAY, 5°F | 31 | 1.8 | 1.85 | 2 | 2 | 2.1 |
Source: NEEP ccASHP list · as of