Skip to content

1HVAC vs COSTWAY heat pumps

Measured against models of the same size and duct type, 1HVAC scores higher on 6 of the 6 ratings. 1HVAC has 70 outdoor models, COSTWAY has 71 outdoor models. 1HVAC has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
1HVAC and COSTWAY on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, 1HVAC scores higher on 6 of the 6 ratings.
  • 1HVAC
  • COSTWAY
  • Other ranked manufacturers
1HVACCOSTWAY

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
Rating1HVACCOSTWAY
Efficiency index62% (higher)median —48% (higher)median — · 26th ranked
COP at 5°F58% (higher)median 2.0050% (higher)median 2.00 · 18th ranked
Capacity retention at 5°F60% (higher)median 78%40% (higher)median 72% · 26th ranked
HSPF271% (higher)median 10.050% (higher)median 9.5 · 17th ranked
SEER265% (higher)median 19.853% (higher)median 21.0 · 16th ranked
EER256% (higher)median 11.940% (higher)median 11.2 · 25th ranked
Heating capacity at 5°F63% (higher)median 21,000 Btu/h42% (higher)median 11,600 Btu/h · 26th ranked
Outdoor models7071
AHRI certifications16675

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
Standard1HVACCOSTWAY
CEE 2025 Tier 1 (Split ASHP)87.1%61 models71.8%51 models
CEE 2026 Tier 1 (Split ASHP)85.7%60 models71.8%51 models
CEE Advanced Tier (Split ASHP)4.3%3 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)74.3%52 models56.3%40 models
DOE Cold Climate Heat Pump Challenge4.3%3 models0%0 models
ENERGY STAR Cold Climate77.1%54 models26.8%19 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • 1HVAC
  • COSTWAY
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct type1HVACCOSTWAY
Ducted, up to 1.5 tons8 · index 75%1 · index 53%
Ducted, 2 tons8 · index 64%1 · index 37%
Ducted, 2.5 to 3 tons12 · index 65%6 · index 61%
Ducted, 3.5 to 4.5 tons17 · index 65%2 · index 46%
Ducted, 5 tons and up1 · index 63%None
Non-ducted, up to 1.5 tons22 · index 61%46 · index 44%
Non-ducted, 2 tons6 · index 55%12 · index 49%
Non-ducted, 2.5 to 3 tons9 · index 49%7 · index 56%
Non-ducted, 3.5 to 4.5 tons6 · index 53%None
Non-ducted, 5 tons and up1 · index 59%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct type1HVACCold-climate score, best modelCOSTWAYCold-climate score, best model
Ducted, up to 1.5 tons86.9(50 is the typical model of its size class) (higher)ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB7 of 8 models qualify · AHRI 21698082149.0(50 is the typical model of its size class)FP11133US1 of 1 models qualify · AHRI 218082696
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models qualify · AHRI 21603228142.0(50 is the typical model of its size class)FP11018USwith ducted air handler FP11021US1 of 1 models qualify · AHRI 217169696
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC11 of 12 models qualify · AHRI 21603228264.6(50 is the typical model of its size class)FP10982USwith ducted air handler FP10985US6 of 6 models qualify · AHRI 217221416
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class) (higher)ACIQ-60-HP32with ducted air handler ACIQ-60-AH3217 of 17 models qualify · AHRI 21538723764.7(50 is the typical model of its size class)FP10983USwith ducted air handler FP10986US2 of 2 models qualify · AHRI 217221417
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD14 of 22 models qualify · AHRI 21603226780.7(50 is the typical model of its size class)FP10897US-12WHwith ductless indoor unit FP10897US-22WH25 of 46 models qualify · AHRI 215876635
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24CC-HH-MC4 of 6 models qualify · AHRI 21603227578.3(50 is the typical model of its size class)FP10898US-12WHwith ductless indoor unit FP10898US-22WH3 of 12 models qualify · AHRI 217178697
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD6 of 9 models qualify · AHRI 21603228958.3(50 is the typical model of its size class)FP10840US-WH7 of 7 models qualify · AHRI 216771328
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class)ACIQ-48Z-HH-M6C6 of 6 models qualify · AHRI 216032306No models in this size class
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct type1HVACAll-around score, best modelCOSTWAYAll-around score, best model
Ducted, up to 1.5 tons86.9(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC8 of 8 models have all five ratings · AHRI 21603227853.1(50 is the typical model of its size class)FP11133US1 of 1 models have all five ratings · AHRI 218082696
Ducted, 2 tons78.6(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC8 of 8 models have all five ratings · AHRI 21603228137.0(50 is the typical model of its size class)FP11018USwith ducted air handler FP11021US1 of 1 models have all five ratings · AHRI 217169696
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C12 of 12 models have all five ratings · AHRI 21603230267.9(50 is the typical model of its size class)FP10982USwith ducted air handler FP10985US6 of 6 models have all five ratings · AHRI 217221416
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)ES-48Z-M6C17 of 17 models have all five ratings · AHRI 21603232054.4(50 is the typical model of its size class)FP10983USwith ducted air handler FP10986US2 of 2 models have all five ratings · AHRI 217221417
Ducted, 5 tons and up63.2(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032323No models in this size class
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD22 of 22 models have all five ratings · AHRI 21603226784.3(50 is the typical model of its size class)FP10897US-12WHwith ductless indoor unit FP10897US-22WH41 of 46 models have all five ratings · AHRI 215876635
Non-ducted, 2 tons78.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24W-HH-MD6 of 6 models have all five ratings · AHRI 21603227187.2(50 is the typical model of its size class) (higher)FP10898US-12WHwith ductless indoor unit FP10898US-22WH11 of 12 models have all five ratings · AHRI 217178697
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M5C9 of 9 models have all five ratings · AHRI 21603230167.4(50 is the typical model of its size class)FP10840US-WH7 of 7 models have all five ratings · AHRI 216771328
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class)ACIQ-48Z-HH-M6C6 of 6 models have all five ratings · AHRI 216032304No models in this size class
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032322No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
Rating1HVACCOSTWAY
COP at 5°Fbeats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tonsbeats 90% · 2.25FP10897US-12WHNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 126%ACIQ-09ZPL-HP230CNon-ducted, up to 1.5 tonsbeats 81% · 90%FP10841US-WHNon-ducted, 2 tons
HSPF2beats 99% · 14.8ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tonsbeats 96% · 10.5FP11135USAlso listed as FP11135USDucted, 2.5 to 3 tons
SEER2beats 97% · 25.0ES-27Z-M4CNon-ducted, 2.5 to 3 tonsbeats 98% · 21.0FP11134USAlso listed as FP11134USDucted, 2.5 to 3 tons
EER2beats 99% · 18.0ACIQ-06ZPL-HP230CNon-ducted, up to 1.5 tonsbeats 97% · 14.0FP10898US-12WHNon-ducted, 2 tons
Heating capacity at 5°Fbeats 98% · 19,600 Btu/hACIQ-18-HPDDucted, up to 1.5 tonsbeats 89% · 16,000 Btu/hFP11133USNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
1HVAC vs COSTWAY: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • 1HVAC (median, middle 50%)
  • COSTWAY (median, middle 50%)
Heating capacity, % of its 47°F maximum68%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
1HVAC: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F69100%100%100%100%100%
1HVAC, 17°F6965%68%73%79%87%
1HVAC, 5°F6957%60%68%80%82%
1HVAC: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F692.933.13.283.513.68
1HVAC, 17°F692.012.222.362.52.7
1HVAC, 5°F691.851.9122.12.31
COSTWAY: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
COSTWAY, 47°F31100%100%100%100%100%
COSTWAY, 17°F3170%72%73%76%78%
COSTWAY, 5°F3159%64%66%70%72%
COSTWAY: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
COSTWAY, 47°F312.472.953.33.513.66
COSTWAY, 17°F311.912.12.22.252.4
COSTWAY, 5°F311.81.85222.1

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy