Both views use the same certified data. This device remembers your choice.
1HVAC vs COSTWAY: heat pump ratings compared
Against heat pumps of the same size and type, a typical 1HVAC model beats 62% and a typical COSTWAY model 48%. 1HVAC rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
1HVAC
62%
of similar heat pumps beaten by its typical model
Well above average70 models listed
COSTWAY
48%
of similar heat pumps beaten by its typical model
About average71 models listed
- Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 58%COSTWAY: Beats 50%
- Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 60%COSTWAY: Beats 40%
- Winter-long heating efficiencyHSPF21HVAC: Beats 71%COSTWAY: Beats 50%
- Summer-long cooling efficiencySEER21HVAC: Beats 65%COSTWAY: Beats 53%
- Hot-day cooling efficiencyEER21HVAC: Beats 56%COSTWAY: Beats 40%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- 1HVAC
- 87%
- COSTWAY
- 72%
Xcel CC
- 1HVAC
- 74%
- COSTWAY
- 56%
CEE Advanced
- 1HVAC
- 4%
- COSTWAY
- 0%
ENERGY STAR CC
- 1HVAC
- 77%
- COSTWAY
- 27%
All-around best, ductless 2.5 to 3 tons
Showing Ductless, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling). What size is my system?
1HVAC
- 1ACIQ-36Z-HH-M5C1HVAC3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 78.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2ACIQ-27Z-HH-M4C1HVAC2.5 tons · 27,000 Btu/h · DuctlessCold-climate pick, score 73.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Great
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 12.5 (EER2)
- Great
- 3ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD1HVAC3 tons · 36,400 Btu/h · DuctlessCold-climate pick, score 89.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 104% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Great
- Winter efficiency
- 10.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 12.0 (EER2)
- Good
COSTWAY
- 1FP10840US-WHCOSTWAY2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 58.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 12.5 (EER2)
- Great
- 2FP11134USCOSTWAYAlso listed as FP11134US2.5 tons · 27,000 Btu/h · DuctlessCold-climate pick, score 58.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Great
- Cooling efficiency
- 24.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3FP10842US-WHCOSTWAY3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 52.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 12.3 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view