Skip to content

ALBOTT vs K&A: heat pump ratings compared

Against heat pumps of the same size and type, a typical ALBOTT model beats 30% and a typical K&A model 31%. K&A rates slightly higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

ALBOTT

30%

of similar heat pumps beaten by its typical model

Well below average

23 models listed

K&A

31%

of similar heat pumps beaten by its typical model

Well below average

23 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FALBOTT: Beats 56%K&A: Beats 32%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FALBOTT: Beats 20%K&A: Beats 39%
  • Winter-long heating efficiencyHSPF2ALBOTT: Beats 20%K&A: Beats 34%
  • Summer-long cooling efficiencySEER2ALBOTT: Beats 28%K&A: Beats 28%
  • Hot-day cooling efficiencyEER2ALBOTT: Beats 28%K&A: Beats 30%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    ALBOTT
    52%
    K&A
    17%
  • Xcel CC

    ALBOTT
    26%
    K&A
    17%
  • CEE Advanced

    ALBOTT
    0%
    K&A
    0%
  • ENERGY STAR CC

    ALBOTT
    9%
    K&A
    0%

All-around best, ductless up to 1.5 tons

ALBOTT

  1. 1BI08W6-1B5A0ALBOTT1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 63.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    78% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    25.0 (SEER2)
    Great
    Hot-day cooling
    11.7 (EER2)
    Below the middle
    64.3score / 100Heating 64 · Cooling 65
  2. 2SAC-H220-12KOwith ductless indoor unit SAC-H220-12KIALBOTT1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.15 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    51.7score / 100Heating 56 · Cooling 47
  3. 3SAC-H220-18KOwith ductless indoor unit SAC-H220-18KIALBOTT1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 65% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    66% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.17 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Below the middle
    Cooling efficiency
    21.0 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Below the middle
    45.5score / 100Heating 44 · Cooling 47

K&A

  1. 1MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S2K&A1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 69% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    70% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    23.4score / 100Heating 38 · Cooling 9
  2. 2MAJESTIC-18K220V-S2with ductless indoor unit MAJESTIC-18K220V-S2K&A1.5 tons · 17,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    10.6score / 100Heating 13 · Cooling 9
  3. 3MAJESTIC-12K220V-S2with ductless indoor unit MAJESTIC-12K220V-S2K&A1 ton · 11,500 Btu/h · DuctlessNot a cold-climate pick: keeps 60% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    61% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.5 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    9.5 (EER2)
    Below the middle
    8.9score / 100Heating 9 · Cooling 9

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter