Both views use the same certified data. This device remembers your choice.
AUX vs Fujitsu: heat pump ratings compared
Against heat pumps of the same size and type, a typical AUX model beats 49% and a typical Fujitsu model 53%. Fujitsu rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AUX
49%
of similar heat pumps beaten by its typical model
About average189 models listed
Fujitsu
53%
of similar heat pumps beaten by its typical model
About average180 models listed
- Efficiency on a 5°F dayCOP at 5°FAUX: Beats 60%Fujitsu: Beats 58%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAUX: Beats 52%Fujitsu: Beats 48%
- Winter-long heating efficiencyHSPF2AUX: Beats 40%Fujitsu: Beats 45%
- Summer-long cooling efficiencySEER2AUX: Beats 48%Fujitsu: Beats 44%
- Hot-day cooling efficiencyEER2AUX: Beats 39%Fujitsu: Beats 48%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- AUX
- 68%
- Fujitsu
- 33%
Xcel CC
- AUX
- 66%
- Fujitsu
- 30%
CEE Advanced
- AUX
- 1%
- Fujitsu
- 8%
ENERGY STAR CC
- AUX
- 47%
- Fujitsu
- 29%
All-around best, ductless 3.5 to 4.5 tons
Showing Ductless, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
AUX
- 1ASUM42HPMULOAUX3.5 tons · 42,000 Btu/h · DuctlessCold-climate pick, score 60.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.05 (COP at 5°F)
- Good
- Winter efficiency
- 10.3 (HSPF2)
- Good
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 12.4 (EER2)
- Great
- 2AM5-H42/2DR3BAUX3.5 tons · 42,000 Btu/h · DuctlessCold-climate pick, score 50.9Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.5 (HSPF2)
- Good
- Cooling efficiency
- 24.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
Fujitsu
- 1AOUH42KUAH1with ductless indoor unit AUUH42KUASFujitsu3.5 tons · 42,000 Btu/h · DuctlessCold-climate pick, score 77.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 102% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Good
- Cooling efficiency
- 22.0 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2AOUK048MSAN7Fujitsu4 tons · 48,000 Btu/h · DuctlessCold-climate pick, score 52.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.36 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.8 (HSPF2)
- Below the middle
- Cooling efficiency
- 23.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 3AOUH45KWAH5Fujitsu3.5 tons · 43,000 Btu/h · DuctlessCold-climate pick, score 71.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 22.0 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view