Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bestcold vs DENALI AIRE: heat pump ratings compared
Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical DENALI AIRE model 52%. DENALI AIRE rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Bestcold
46%
of similar heat pumps beaten by its typical model
About average79 models listed
DENALI AIRE
52%
of similar heat pumps beaten by its typical model
About average5 models listed
- Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 45%DENALI AIRE: Beats 41%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 43%DENALI AIRE: Beats 60%
- Winter-long heating efficiencyHSPF2Bestcold: Beats 48%DENALI AIRE: Beats 45%
- Summer-long cooling efficiencySEER2Bestcold: Beats 51%DENALI AIRE: Beats 55%
- Hot-day cooling efficiencyEER2Bestcold: Beats 39%DENALI AIRE: Beats 56%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Bestcold
- 68%
- DENALI AIRE
- 80%
Xcel CC
- Bestcold
- 66%
- DENALI AIRE
- 80%
CEE Advanced
- Bestcold
- 1%
- DENALI AIRE
- 0%
ENERGY STAR CC
- Bestcold
- 10%
- DENALI AIRE
- 80%
Top cold-climate picks, ducted 3.5–4.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 3.5–4.5 tons (39,000–56,999 Btu/h cooling). What size is my system?
Bestcold
- 1MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-IBestcold4 tons · 48,000 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.8 (HSPF2)
- Great
- 2MYUA48NA23BCH19-Owith ducted air handler MYUA48NA23BCH19-IBestcold4 tons · 48,000 Btu/h · DuctedKeeps 73% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.8 (HSPF2)
- Great
- 3MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-IBestcold4 tons · 47,000 Btu/h · DuctedKeeps 72% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.2 (HSPF2)
- Great
DENALI AIRE
No ducted, 3.5–4.5 tons model from DENALI AIRE.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view