Both views use the same certified data. This device remembers your choice.
Bestcold vs MRCOOL: heat pump ratings compared
Against heat pumps of the same size and type, a typical Bestcold model beats 46% and a typical MRCOOL model 54%. MRCOOL rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Bestcold
46%
of similar heat pumps beaten by its typical model
About average96 models listed
MRCOOL
54%
of similar heat pumps beaten by its typical model
About average92 models listed
- Efficiency on a 5°F dayCOP at 5°FBestcold: Beats 43%MRCOOL: Beats 50%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBestcold: Beats 46%MRCOOL: Beats 51%
- Winter-long heating efficiencyHSPF2Bestcold: Beats 47%MRCOOL: Beats 57%
- Summer-long cooling efficiencySEER2Bestcold: Beats 51%MRCOOL: Beats 55%
- Hot-day cooling efficiencyEER2Bestcold: Beats 40%MRCOOL: Beats 51%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Bestcold
- 66%
- MRCOOL
- 67%
Xcel CC
- Bestcold
- 63%
- MRCOOL
- 58%
CEE Advanced
- Bestcold
- 1%
- MRCOOL
- 0%
ENERGY STAR CC
- Bestcold
- 22%
- MRCOOL
- 57%
All-around best, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Bestcold
- 1MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-IBestcold4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 72.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 72% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Winter efficiency
- 9.2 (HSPF2)
- Great
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 11.5 (EER2)
- Good
- 2MYUA48NA23BCH19-Owith ducted air handler MYUA48NA23BCH19-IBestcold4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 73.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Great
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 3MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-IBestcold4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 76.9Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Winter efficiency
- 9.8 (HSPF2)
- Great
- Cooling efficiency
- 17.5 (SEER2)
- Good
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
MRCOOL
- 1MULTI6-48HP230C-OMRCOOL4 tons · 45,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 2DIY-MULTI6-55HP230D-OMRCOOL4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 73.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 3DIY-MULTI6-48HP230D-OMRCOOL3.5 tons · 43,000 Btu/h · DuctedCold-climate pick, score 70.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view