Both views use the same certified data. This device remembers your choice.
CanAir vs Sinclair: heat pump ratings compared
Against heat pumps of the same size and type, a typical CanAir model beats 63% and a typical Sinclair model 50%. CanAir rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
CanAir
63%
of similar heat pumps beaten by its typical model
Well above average51 models listed
Sinclair
50%
of similar heat pumps beaten by its typical model
About average53 models listed
- Efficiency on a 5°F dayCOP at 5°FCanAir: Beats 63%Sinclair: Beats 57%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCanAir: Beats 61%Sinclair: Beats 40%
- Winter-long heating efficiencyHSPF2CanAir: Beats 73%Sinclair: Beats 50%
- Summer-long cooling efficiencySEER2CanAir: Beats 63%Sinclair: Beats 48%
- Hot-day cooling efficiencyEER2CanAir: Beats 58%Sinclair: Beats 53%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- CanAir
- 88%
- Sinclair
- 55%
Xcel CC
- CanAir
- 92%
- Sinclair
- 47%
CEE Advanced
- CanAir
- 2%
- Sinclair
- 2%
ENERGY STAR CC
- CanAir
- 78%
- Sinclair
- 0%
Top cold-climate picks, ductless 2 tons
Showing Ductless, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
CanAir
- 14C28SCH24H21with ductless indoor unit 4C28SEQ24H21CanAir2 tons · 23,400 Btu/h · DuctlessKeeps 95% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 95% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.23 (COP at 5°F)
- Great
- Seasonal efficiency
- 11.6 (HSPF2)
- Top 10%
- 24C25SCH24H21with ductless indoor unit 4C28SEH24H21CanAir2 tons · 24,000 Btu/h · DuctlessKeeps 78% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.54 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 34C22SCH24H21with ductless indoor unit 4C22SEH24H21CanAir2 tons · 24,000 Btu/h · DuctlessKeeps 71% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.14 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.3 (HSPF2)
- Below the middle
Sinclair
- 1SNCXF-DMO-24-230-HXwith ductless indoor unit SNCXF-DWM-24-230-HSinclair2 tons · 23,000 Btu/h · DuctlessKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 13.3 (HSPF2)
- Top 10%
- 2SNCXF-DMO-24-230-HSwith ductless indoor unit SNCXF-DWM-24-230-HSinclair2 tons · 24,000 Btu/h · DuctlessKeeps 71% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.15 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Good
- 3SNCXF-DMO-24-230-MSwith ductless indoor unit SNCXF-DWM-24-230-MSinclair2 tons · 24,000 Btu/h · DuctlessKeeps 71% of its heat at 5°FMeets Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.11 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.0 (HSPF2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view