CanAir vs Sinclair heat pumps

Measured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings. CanAir has 51 outdoor models, Sinclair has 53 outdoor models. CanAir and Sinclair have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CanAir and Sinclair on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings.
  • CanAir
  • Sinclair
  • Other ranked manufacturers
CanAirSinclair

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCanAirSinclair
Efficiency index63% (higher)median —50% (higher)median —
COP at 5°F63% (higher)median 2.0057% (higher)median 2.00
Capacity retention at 5°F61% (higher)median 81%40% (higher)median 67%
HSPF273% (higher)median 10.050% (higher)median 9.1
SEER263% (higher)median 20.548% (higher)median 19.4
EER258% (higher)median 12.053% (higher)median 11.5
Heating capacity at 5°F62% (higher)median 18,000 Btu/h45% (higher)median 14,800 Btu/h
Outdoor models5153
AHRI certifications165295

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCanAirSinclair
CEE 2025 Tier 1 (Split ASHP)88.2%45 models54.7%29 models
CEE 2026 Tier 1 (Split ASHP)88.2%45 models52.8%28 models
CEE Advanced Tier (Split ASHP)2%1 models1.9%1 models
Xcel Energy Colorado cold-climate ASHP (2025)92.2%47 models47.2%25 models
DOE Cold Climate Heat Pump Challenge2%1 models1.9%1 models
ENERGY STAR Cold Climate78.4%40 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • CanAir
  • Sinclair
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCanAirSinclair
Ducted, up to 1.5 tons9 · index 77%4 · index 55%
Ducted, 2 tons4 · index 71%4 · index 31%
Ducted, 2.5 to 3 tons9 · index 65%8 · index 45%
Ducted, 3.5 to 4.5 tons8 · index 66%10 · index 45%
Ducted, 5 tons and up1 · index 66%1 · index 63%
Non-ducted, up to 1.5 tons25 · index 62%21 · index 55%
Non-ducted, 2 tons4 · index 57%5 · index 52%
Non-ducted, 2.5 to 3 tons9 · index 56%6 · index 48%
Non-ducted, 3.5 to 4.5 tons7 · index 47%3 · index 57%
Non-ducted, 5 tons and upNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCanAirCold-climate score, best modelSinclairCold-climate score, best model
Ducted, up to 1.5 tons82.9(50 is the typical model of its size class) (higher)4C28SCH18H21with ducted air handler 4C28SEDH18H219 of 9 models qualify · AHRI 21795897473.2(50 is the typical model of its size class)SNCXF-DMZ-18-230-HS2 of 4 models qualify · AHRI 218613264
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)4C28SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models qualify · AHRI 21795897548.1(50 is the typical model of its size class)SNCXF-DMZ-27-230-HS1 of 4 models qualify · AHRI 218613268
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)4C28LCH36H21with ducted air handler 4C28LEDH36H216 of 9 models qualify · AHRI 21795897682.7(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX3 of 8 models qualify · AHRI 218613292
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)4C28MC648H218 of 8 models qualify · AHRI 21544973482.6(50 is the typical model of its size class)SNCXF-DMZ-48-230-HX3 of 10 models qualify · AHRI 218613296
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2123 of 25 models qualify · AHRI 21544971694.6(50 is the typical model of its size class)SNCXF-DMO-06-230-HXwith ductless indoor unit SNCXF-DWM-06-230-H13 of 21 models qualify · AHRI 218613255
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)4C28SCH24H21with ductless indoor unit 4C28SEQ24H214 of 4 models qualify · AHRI 21795895677.6(50 is the typical model of its size class)SNCXF-DMO-24-230-HXwith ductless indoor unit SNCXF-DWM-24-230-H5 of 5 models qualify · AHRI 218613260
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)4C28LCH36H21with ductless indoor unit 4C28LEP36H217 of 9 models qualify · AHRI 21795893772.8(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX4 of 6 models qualify · AHRI 218613293
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)4C28MC648H216 of 7 models qualify · AHRI 21544973570.3(50 is the typical model of its size class)SNCXF-DMZ-60-230-HX3 of 3 models qualify · AHRI 218613301
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCanAirAll-around score, best modelSinclairAll-around score, best model
Ducted, up to 1.5 tons87.1(50 is the typical model of its size class) (higher)4C28SCH09H21with ducted air handler 4C28SEDL09H219 of 9 models have all five ratings · AHRI 21795896277.9(50 is the typical model of its size class)SNCXF-DMZ-18-230-HX3 of 3 models have all five ratings · AHRI 218613284
Ducted, 2 tons78.9(50 is the typical model of its size class) (higher)4C25SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models have all five ratings · AHRI 21795896864.6(50 is the typical model of its size class)SNCXF-DMZ-27-230-HS4 of 4 models have all five ratings · AHRI 218613268
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)4C28MC536H219 of 9 models have all five ratings · AHRI 21544973183.9(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX8 of 8 models have all five ratings · AHRI 218613292
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)4C25MC548H218 of 8 models have all five ratings · AHRI 21795899385.3(50 is the typical model of its size class)SNCXF-DMZ-48-230-HS11 of 11 models have all five ratings · AHRI 218613276
Ducted, 5 tons and up65.9(50 is the typical model of its size class) (higher)4C25LCH60H21with ducted air handler 4C28LEDH60H211 of 1 models have all five ratings · AHRI 21795897163.2(50 is the typical model of its size class)SNCXF-DMZ-60-230-HS1 of 1 models have all five ratings · AHRI 218613280
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2124 of 25 models have all five ratings · AHRI 21544971694.5(50 is the typical model of its size class)SNCXF-DMO-06-230-HXwith ductless indoor unit SNCXF-DWM-06-230-H21 of 21 models have all five ratings · AHRI 218613255
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)4C25SCH24H21with ductless indoor unit 4C28SEH24H214 of 4 models have all five ratings · AHRI 21582839075.9(50 is the typical model of its size class)SNCXF-DMO-24-230-HSwith ductless indoor unit SNCXF-DWM-24-230-H5 of 5 models have all five ratings · AHRI 218613254
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)4C28MC536H219 of 9 models have all five ratings · AHRI 21544973067.0(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX6 of 6 models have all five ratings · AHRI 218613291
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)4C28MC648H217 of 7 models have all five ratings · AHRI 21544973362.6(50 is the typical model of its size class)SNCXF-DMZ-60-230-HX3 of 3 models have all five ratings · AHRI 218613299
Non-ducted, 5 tons and upNo models in this size class32.9(50 is the typical model of its size class)SNCXF-DMZ-60-230-HS1 of 1 models have all five ratings · AHRI 218613279

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCanAirSinclair
COP at 5°Fbeats 99% · 2.514C25SCH12H21Non-ducted, up to 1.5 tonsbeats 95% · 2.35SNCXF-DMO-12-230-HSNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 120%4C28SCH09H21Ducted, up to 1.5 tonsbeats 95% · 104%SNCXF-DMZ-36-230-HXNon-ducted, 2.5 to 3 tons
HSPF2beats 99% · 14.84C28SCH06H21Non-ducted, up to 1.5 tonsbeats 99% · 11.0SNCXF-DMZ-48-230-HXDucted, 3.5 to 4.5 tons
SEER2beats 99% · 33.34C35SCH09H21Non-ducted, up to 1.5 tonsbeats 96% · 20.4SNCXF-DMZ-48-230-HSDucted, 3.5 to 4.5 tons
EER2beats 99% · 18.04C28SCH06H21Non-ducted, up to 1.5 tonsbeats 96% · 16.0SNCXF-DMO-06-230-HXNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/h4C35SCH18H21Non-ducted, up to 1.5 tonsbeats 95% · 37,400 Btu/hSNCXF-DMZ-36-230-HXNon-ducted, 2.5 to 3 tons