Skip to content

CanAir vs ELIOS heat pumps

Measured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings. CanAir has 51 outdoor models, ELIOS has 51 outdoor models. CanAir and ELIOS have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CanAir and ELIOS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings.
  • CanAir
  • ELIOS
  • Other ranked manufacturers
CanAirELIOS

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCanAirELIOS
Efficiency index63% (higher)median —57% (higher)median —
COP at 5°F63% (higher)median 2.0057% (higher)median 2.00
Capacity retention at 5°F61% (higher)median 81%55% (higher)median 74%
HSPF273% (higher)median 10.065% (higher)median 9.5
SEER263% (higher)median 20.559% (higher)median 20.0
EER258% (higher)median 12.049% (higher)median 11.7
Heating capacity at 5°F62% (higher)median 18,000 Btu/h60% (higher)median 19,000 Btu/h
Outdoor models5151
AHRI certifications165111

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCanAirELIOS
CEE 2025 Tier 1 (Split ASHP)88.2%45 models84.3%43 models
CEE 2026 Tier 1 (Split ASHP)88.2%45 models84.3%43 models
CEE Advanced Tier (Split ASHP)2%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)92.2%47 models78.4%40 models
DOE Cold Climate Heat Pump Challenge2%1 models0%0 models
ENERGY STAR Cold Climate78.4%40 models74.5%38 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • CanAir
  • ELIOS
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCanAirELIOS
Ducted, up to 1.5 tons9 · index 77%9 · index 67%
Ducted, 2 tons4 · index 71%6 · index 54%
Ducted, 2.5 to 3 tons9 · index 65%10 · index 58%
Ducted, 3.5 to 4.5 tons8 · index 66%5 · index 65%
Ducted, 5 tons and up1 · index 66%1 · index 66%
Non-ducted, up to 1.5 tons25 · index 62%17 · index 56%
Non-ducted, 2 tons4 · index 57%5 · index 53%
Non-ducted, 2.5 to 3 tons9 · index 56%9 · index 45%
Non-ducted, 3.5 to 4.5 tons7 · index 47%3 · index 50%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCanAirCold-climate score, best modelELIOSCold-climate score, best model
Ducted, up to 1.5 tons82.9(50 is the typical model of its size class) (higher)4C28SCH18H21with ducted air handler 4C28SEDH18H219 of 9 models qualify · AHRI 21795897481.7(50 is the typical model of its size class)ESHEA09C2AN1with ducted air handler GDHRA09C2AS17 of 9 models qualify · AHRI 216046626
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)4C28SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models qualify · AHRI 21795897577.1(50 is the typical model of its size class)ESHEA24C2AN1with ducted air handler GDHRA24C2AS16 of 6 models qualify · AHRI 216046629
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)4C28LCH36H21with ducted air handler 4C28LEDH36H216 of 9 models qualify · AHRI 21795897682.7(50 is the typical model of its size class)EXHZA3652AV17 of 10 models qualify · AHRI 217900393
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)4C28MC648H218 of 8 models qualify · AHRI 21544973482.6(50 is the typical model of its size class)EXHZA4862AV15 of 5 models qualify · AHRI 217900396
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2123 of 25 models qualify · AHRI 21544971681.4(50 is the typical model of its size class)ESHEA09C2AN1with ductless indoor unit GKHRA09C2AS114 of 17 models qualify · AHRI 216046618
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)4C28SCH24H21with ductless indoor unit 4C28SEQ24H214 of 4 models qualify · AHRI 21795895677.6(50 is the typical model of its size class)ESHMA24C2AN1with ductless indoor unit EWHMA24C2AS15 of 5 models qualify · AHRI 216046616
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)4C28LCH36H21with ductless indoor unit 4C28LEP36H217 of 9 models qualify · AHRI 21795893772.8(50 is the typical model of its size class)EXHZA3652AV17 of 9 models qualify · AHRI 217900394
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)4C28MC648H216 of 7 models qualify · AHRI 21544973569.0(50 is the typical model of its size class)EXHZA4862AV13 of 3 models qualify · AHRI 217900397

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCanAirAll-around score, best modelELIOSAll-around score, best model
Ducted, up to 1.5 tons87.1(50 is the typical model of its size class) (higher)4C28SCH09H21with ducted air handler 4C28SEDL09H219 of 9 models have all five ratings · AHRI 21795896281.3(50 is the typical model of its size class)ESHEA09C2AN1with ducted air handler GDHRA09C2AS19 of 9 models have all five ratings · AHRI 216046626
Ducted, 2 tons78.9(50 is the typical model of its size class)4C25SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models have all five ratings · AHRI 21795896878.9(50 is the typical model of its size class)ESHEA24C2AN1with ducted air handler GDHRA24C2AS16 of 6 models have all five ratings · AHRI 216046629
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)4C28MC536H219 of 9 models have all five ratings · AHRI 21544973183.9(50 is the typical model of its size class)EXHZA3652AV110 of 10 models have all five ratings · AHRI 217900393
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)4C25MC548H218 of 8 models have all five ratings · AHRI 21795899385.3(50 is the typical model of its size class)EXHSA4862AV15 of 5 models have all five ratings · AHRI 216046646
Ducted, 5 tons and up65.9(50 is the typical model of its size class)4C25LCH60H21with ducted air handler 4C28LEDH60H211 of 1 models have all five ratings · AHRI 21795897165.9(50 is the typical model of its size class)ESHUA60R2AN1with ducted air handler GDHLA60R2AS11 of 1 models have all five ratings · AHRI 216046632
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2124 of 25 models have all five ratings · AHRI 21544971680.3(50 is the typical model of its size class)ESHMA09C2AN1with ductless indoor unit EWHMA09C2AS117 of 17 models have all five ratings · AHRI 216046613
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)4C25SCH24H21with ductless indoor unit 4C28SEH24H214 of 4 models have all five ratings · AHRI 21582839074.3(50 is the typical model of its size class)ESHMA24C2AN1with ductless indoor unit EWHMA24C2AS15 of 5 models have all five ratings · AHRI 216046616
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)4C28MC536H219 of 9 models have all five ratings · AHRI 21544973067.0(50 is the typical model of its size class)EXHZA3652AV19 of 9 models have all five ratings · AHRI 217900392
Non-ducted, 3.5 to 4.5 tons75.4(50 is the typical model of its size class) (higher)4C28MC648H217 of 7 models have all five ratings · AHRI 21544973362.4(50 is the typical model of its size class)EXHZA4862AV13 of 3 models have all five ratings · AHRI 217900395

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCanAirELIOS
COP at 5°Fbeats 99% · 2.514C25SCH12H21Non-ducted, up to 1.5 tonsbeats 99% · 2.51ESHEA12C2AN1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 120%4C28SCH09H21Ducted, up to 1.5 tonsbeats 98% · 116%ESHMA15C2AN1Non-ducted, up to 1.5 tons
HSPF2beats 99% · 14.84C28SCH06H21Non-ducted, up to 1.5 tonsbeats 99% · 11.0EXHZA4862AV1Ducted, 3.5 to 4.5 tons
SEER2beats 99% · 33.34C35SCH09H21Non-ducted, up to 1.5 tonsbeats 96% · 20.4EXHSA4862AV1Ducted, 3.5 to 4.5 tons
EER2beats 99% · 18.04C28SCH06H21Non-ducted, up to 1.5 tonsbeats 92% · 15.0ESHMA09C2AN1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/h4C35SCH18H21Non-ducted, up to 1.5 tonsbeats 98% · 39,000 Btu/hESHMB36R2AN1Ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
CanAir vs ELIOS: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • CanAir (median, middle 50%)
  • ELIOS (median, middle 50%)
Heating capacity, % of its 47°F maximum69%66%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
CanAir: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F51100%100%100%100%100%
CanAir, 17°F5169%73%76%81%86%
CanAir, 5°F5158%63%69%79%82%
CanAir: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F512.943.13.253.533.6
CanAir, 17°F512.032.232.352.52.62
CanAir, 5°F511.891.9722.172.34
ELIOS: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ELIOS, 47°F44100%100%100%100%100%
ELIOS, 17°F4462%67%73%81%86%
ELIOS, 5°F4456%61%66%74%83%
ELIOS: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ELIOS, 47°F442.753.043.223.573.74
ELIOS, 17°F4422.192.32.492.64
ELIOS, 5°F441.81.9122.072.27

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter