Measured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings. BOREAL has 50 outdoor models, CanAir has 51 outdoor models. BOREAL and CanAir have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BOREAL and CanAir on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CanAir scores higher on 6 of the 6 ratings.
  • BOREAL
  • CanAir
  • Other ranked manufacturers
BOREALCanAir

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBOREALCanAir
Efficiency index53%median —63%median —
COP at 5°F43%median 1.9563%median 2.00
Capacity retention at 5°F59%median 78%61%median 81%
HSPF241%median 9.073%median 10.0
SEER259%median 19.063%median 20.5
EER256%median 11.957%median 12.0
Heating capacity at 5°F57%median 17,000 Btu/h62%median 18,000 Btu/h
Outdoor models5051
AHRI certifications145165

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBOREALCanAir
CEE 2025 Tier 1 (Split ASHP)86%43 models88.2%45 models
CEE 2026 Tier 1 (Split ASHP)86%43 models88.2%45 models
CEE Advanced Tier (Split ASHP)6%3 models2%1 models
Xcel Energy Colorado cold-climate ASHP (2025)88%44 models92.2%47 models
DOE Cold Climate Heat Pump Challenge6%3 models2%1 models
ENERGY STAR Cold Climate60%30 models78.4%40 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • BOREAL
  • CanAir
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBOREALCanAir
Ducted, up to 1.5 tons9 · index 65%9 · index 77%
Ducted, 2 tons6 · index 58%4 · index 71%
Ducted, 2.5 to 3 tons12 · index 53%9 · index 65%
Ducted, 3.5 to 4.5 tons6 · index 68%8 · index 66%
Ducted, 5 tons and upNone1 · index 66%
Non-ducted, up to 1.5 tons23 · index 47%25 · index 62%
Non-ducted, 2 tons6 · index 50%4 · index 57%
Non-ducted, 2.5 to 3 tons6 · index 43%9 · index 56%
Non-ducted, 3.5 to 4.5 tons2 · index 39%7 · index 47%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBOREALCold-climate score, best modelCanAirCold-climate score, best model
Ducted, up to 1.5 tons70.5(50 is the typical model of its size class)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA8 of 9 models qualify · AHRI 21556026782.7(50 is the typical model of its size class) (higher)4C28SCH18H21with ducted air handler 4C28SEDH18H219 of 9 models qualify · AHRI 217958974
Ducted, 2 tons76.2(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 7 models qualify · AHRI 21542068585.8(50 is the typical model of its size class) (higher)4C28SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models qualify · AHRI 217958975
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH7 of 11 models qualify · AHRI 21746358683.5(50 is the typical model of its size class) (higher)4C28LCH36H21with ducted air handler 4C28LEDH36H216 of 9 models qualify · AHRI 217958976
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class) (higher)ENX60HPJ132OAwith ducted air handler ENX60HPJ132IA5 of 6 models qualify · AHRI 21542068382.6(50 is the typical model of its size class)4C28MC648H218 of 8 models qualify · AHRI 215449734
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons64.7(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA21 of 23 models qualify · AHRI 21542478397.0(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2123 of 25 models qualify · AHRI 215449716
Non-ducted, 2 tons68.5(50 is the typical model of its size class)MUL24HPJ132OA5 of 6 models qualify · AHRI 21542476990.1(50 is the typical model of its size class) (higher)4C28SCH24H21with ductless indoor unit 4C28SEQ24H214 of 4 models qualify · AHRI 217958956
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)MUL36HPJ132OA6 of 6 models qualify · AHRI 21542477189.4(50 is the typical model of its size class) (higher)4C28LCH36H21with ductless indoor unit 4C28LEP36H217 of 9 models qualify · AHRI 217958937
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models qualify · AHRI 21542477273.7(50 is the typical model of its size class) (higher)4C28MC648H216 of 7 models qualify · AHRI 215449735

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBOREALAll-around score, best modelCanAirAll-around score, best model
Ducted, up to 1.5 tons83.9(50 is the typical model of its size class)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA9 of 9 models have all five ratings · AHRI 21556026787.0(50 is the typical model of its size class) (higher)4C28SCH09H21with ducted air handler 4C28SEDL09H219 of 9 models have all five ratings · AHRI 217958962
Ducted, 2 tons68.6(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 6 models have all five ratings · AHRI 21542068578.9(50 is the typical model of its size class) (higher)4C25SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models have all five ratings · AHRI 217958968
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH12 of 12 models have all five ratings · AHRI 21746358683.9(50 is the typical model of its size class) (higher)4C28MC536H219 of 9 models have all five ratings · AHRI 215449731
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class)ENX48HPJ132OAwith ducted air handler ENX48HPJ132IAAlso listed as ENX60HPJ132OA, ARX60HPJ1R32OA6 of 6 models have all five ratings · AHRI 21542068485.3(50 is the typical model of its size class) (higher)4C25MC548H218 of 8 models have all five ratings · AHRI 217958993
Ducted, 5 tons and upNo models in this size class65.9(50 is the typical model of its size class)4C25LCH60H21with ducted air handler 4C28LEDH60H211 of 1 models have all five ratings · AHRI 217958971
Non-ducted, up to 1.5 tons79.8(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA23 of 23 models have all five ratings · AHRI 21542478396.6(50 is the typical model of its size class) (higher)4C28SCH06H21with ductless indoor unit 4C28SEH06H2124 of 25 models have all five ratings · AHRI 215449716
Non-ducted, 2 tons73.1(50 is the typical model of its size class)KUL24HPJ132OAwith ductless indoor unit KUL24HPJ132IA5 of 6 models have all five ratings · AHRI 21542481787.8(50 is the typical model of its size class) (higher)4C25SCH24H21with ductless indoor unit 4C28SEH24H214 of 4 models have all five ratings · AHRI 215828390
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class)MUL30HPJ132OA6 of 6 models have all five ratings · AHRI 21542477078.8(50 is the typical model of its size class) (higher)4C28MC536H219 of 9 models have all five ratings · AHRI 215449730
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models have all five ratings · AHRI 21542477275.5(50 is the typical model of its size class) (higher)4C28MC648H217 of 7 models have all five ratings · AHRI 215449733

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBOREALCanAir
COP at 5°Fbeats 87% · 2.10MUL36HPJ132OANon-ducted, 2.5 to 3 tonsbeats 99% · 2.514C25SCH12H21Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 100%ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 98% · 120%4C28SCH09H21Ducted, up to 1.5 tons
HSPF2beats 91% · 10.5ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 99% · 14.84C28SCH06H21Non-ducted, up to 1.5 tons
SEER2beats 99% · 22.5KUL18HPJ132OAAlso listed as NOV18HPJ132OADucted, up to 1.5 tonsbeats 99% · 33.34C35SCH09H21Non-ducted, up to 1.5 tons
EER2beats 97% · 14.2KUL09HPJ132OAAlso listed as NOV09HPJ132OADucted, up to 1.5 tonsbeats 99% · 18.04C28SCH06H21Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 99% · 22,600 Btu/h4C35SCH18H21Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BOREAL vs CanAir: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BOREAL (median, middle 50%)
  • CanAir (median, middle 50%)
Heating capacity, % of its 47°F maximum69%69%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
BOREAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F45100%100%100%100%100%
BOREAL, 17°F4568%75%82%87%96%
BOREAL, 5°F4559%63%69%76%98%
BOREAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F452.923.173.283.373.47
BOREAL, 17°F452.062.12.32.42.57
BOREAL, 5°F451.81.8522.072.14
CanAir: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F51100%100%100%100%100%
CanAir, 17°F5169%73%76%81%86%
CanAir, 5°F5158%63%69%79%82%
CanAir: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F512.943.13.253.533.6
CanAir, 17°F512.032.232.352.52.62
CanAir, 5°F511.891.9722.172.34

Source: NEEP ccASHP list · as of