Skip to content

AI AIR CONDITIONING vs Sinclair heat pumps

Measured against models of the same size and duct type, AI AIR CONDITIONING scores higher on 6 of the 6 ratings. AI AIR CONDITIONING has 55 outdoor models, Sinclair has 53 outdoor models. AI AIR CONDITIONING and Sinclair have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AI AIR CONDITIONING and Sinclair on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AI AIR CONDITIONING scores higher on 6 of the 6 ratings.
  • AI AIR CONDITIONING
  • Sinclair
  • Other ranked manufacturers
AI AIR C…Sinclair

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAI AIR CONDITIONINGSinclair
Efficiency index63% (higher)median —50% (higher)median —
COP at 5°F62% (higher)median 2.0057% (higher)median 2.00
Capacity retention at 5°F63% (higher)median 82%40% (higher)median 67%
HSPF274% (higher)median 10.050% (higher)median 9.1
SEER263% (higher)median 19.548% (higher)median 19.4
EER258% (higher)median 12.053% (higher)median 11.5
Heating capacity at 5°F65% (higher)median 20,600 Btu/h45% (higher)median 14,800 Btu/h
Outdoor models5553
AHRI certifications189295

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAI AIR CONDITIONINGSinclair
CEE 2025 Tier 1 (Split ASHP)89.1%49 models54.7%29 models
CEE 2026 Tier 1 (Split ASHP)89.1%49 models52.8%28 models
CEE Advanced Tier (Split ASHP)3.6%2 models1.9%1 models
Xcel Energy Colorado cold-climate ASHP (2025)80%44 models47.2%25 models
DOE Cold Climate Heat Pump Challenge3.6%2 models1.9%1 models
ENERGY STAR Cold Climate81.8%45 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • AI AIR CONDITIONING
  • Sinclair
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAI AIR CONDITIONINGSinclair
Ducted, up to 1.5 tons11 · index 78%4 · index 55%
Ducted, 2 tons5 · index 69%4 · index 31%
Ducted, 2.5 to 3 tons13 · index 63%8 · index 45%
Ducted, 3.5 to 4.5 tons12 · index 66%10 · index 45%
Ducted, 5 tons and up2 · index 65%1 · index 63%
Non-ducted, up to 1.5 tons20 · index 68%21 · index 55%
Non-ducted, 2 tons4 · index 57%5 · index 52%
Non-ducted, 2.5 to 3 tons8 · index 50%6 · index 48%
Non-ducted, 3.5 to 4.5 tons7 · index 42%3 · index 57%
Non-ducted, 5 tons and up1 · index 27%1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAI AIR CONDITIONINGCold-climate score, best modelSinclairCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)AO25-06N2-M1Hwith ducted air handler AL-06N2-M110 of 11 models qualify · AHRI 21586678173.2(50 is the typical model of its size class)SNCXF-DMZ-18-230-HS2 of 4 models qualify · AHRI 218613264
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)AO25-24N2-M1Hwith ducted air handler AH-24N2-M15 of 5 models qualify · AHRI 21586678848.1(50 is the typical model of its size class)SNCXF-DMZ-27-230-HS1 of 4 models qualify · AHRI 218613268
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)ASO25-36N2-M2Hwith ducted air handler AH-36N2-M19 of 13 models qualify · AHRI 21586678982.7(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX3 of 8 models qualify · AHRI 218613292
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)A6MO23-48N2-M1H12 of 12 models qualify · AHRI 21586682582.6(50 is the typical model of its size class)SNCXF-DMZ-48-230-HX3 of 10 models qualify · AHRI 218613296
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons94.9(50 is the typical model of its size class) (higher)AO25-06N2-M1Hwith ductless indoor unit A1C-06N2-M115 of 20 models qualify · AHRI 21586677794.6(50 is the typical model of its size class)SNCXF-DMO-06-230-HXwith ductless indoor unit SNCXF-DWM-06-230-H13 of 21 models qualify · AHRI 218613255
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)AO25-24N2-M1Hwith ductless indoor unit AC-24N2-M14 of 4 models qualify · AHRI 21586677477.6(50 is the typical model of its size class)SNCXF-DMO-24-230-HXwith ductless indoor unit SNCXF-DWM-24-230-H5 of 5 models qualify · AHRI 218613260
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class) (higher)ASO25-36N2-M2Hwith ductless indoor unit AF-36N2-M16 of 8 models qualify · AHRI 21586679772.8(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX4 of 6 models qualify · AHRI 218613293
Non-ducted, 3.5 to 4.5 tons70.3(50 is the typical model of its size class)A6MO23-55N2-M1H6 of 7 models qualify · AHRI 21586682970.3(50 is the typical model of its size class)SNCXF-DMZ-60-230-HX3 of 3 models qualify · AHRI 218613301
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAI AIR CONDITIONINGAll-around score, best modelSinclairAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class) (higher)AO25-06N2-M1Hwith ducted air handler AL-06N2-M111 of 11 models have all five ratings · AHRI 21586678177.9(50 is the typical model of its size class)SNCXF-DMZ-18-230-HX3 of 3 models have all five ratings · AHRI 218613284
Ducted, 2 tons78.9(50 is the typical model of its size class) (higher)AO24-24N2-M1with ducted air handler AH-24N2-M15 of 5 models have all five ratings · AHRI 21586675964.6(50 is the typical model of its size class)SNCXF-DMZ-27-230-HS4 of 4 models have all five ratings · AHRI 218613268
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)A5MO23-36N2-M1H13 of 13 models have all five ratings · AHRI 21586682283.9(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX8 of 8 models have all five ratings · AHRI 218613292
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)A6MO21-48N2-M112 of 12 models have all five ratings · AHRI 21586681085.3(50 is the typical model of its size class)SNCXF-DMZ-48-230-HS11 of 11 models have all five ratings · AHRI 218613276
Ducted, 5 tons and up65.9(50 is the typical model of its size class) (higher)ASO24-60N2-M2with ducted air handler AH-60N2-M12 of 2 models have all five ratings · AHRI 21586676263.2(50 is the typical model of its size class)SNCXF-DMZ-60-230-HS1 of 1 models have all five ratings · AHRI 218613280
Non-ducted, up to 1.5 tons94.5(50 is the typical model of its size class)AO25-06N2-M1Hwith ductless indoor unit AW25-06N2-M119 of 20 models have all five ratings · AHRI 21586673494.5(50 is the typical model of its size class)SNCXF-DMO-06-230-HXwith ductless indoor unit SNCXF-DWM-06-230-H21 of 21 models have all five ratings · AHRI 218613255
Non-ducted, 2 tons75.9(50 is the typical model of its size class)AO24-24N2-M1with ductless indoor unit AW25-24N2-M14 of 4 models have all five ratings · AHRI 21586673375.9(50 is the typical model of its size class)SNCXF-DMO-24-230-HSwith ductless indoor unit SNCXF-DWM-24-230-H5 of 5 models have all five ratings · AHRI 218613254
Non-ducted, 2.5 to 3 tons67.1(50 is the typical model of its size class) (higher)ASO25-36N2-M2Hwith ductless indoor unit AF-36N2-M18 of 8 models have all five ratings · AHRI 21586679767.0(50 is the typical model of its size class)SNCXF-DMZ-36-230-HX6 of 6 models have all five ratings · AHRI 218613291
Non-ducted, 3.5 to 4.5 tons62.6(50 is the typical model of its size class)A6MO23-55N2-M1H7 of 7 models have all five ratings · AHRI 21586682762.6(50 is the typical model of its size class)SNCXF-DMZ-60-230-HX3 of 3 models have all five ratings · AHRI 218613299
Non-ducted, 5 tons and up32.9(50 is the typical model of its size class)A6MO21-60N2-M11 of 1 models have all five ratings · AHRI 21586681232.9(50 is the typical model of its size class)SNCXF-DMZ-60-230-HS1 of 1 models have all five ratings · AHRI 218613279

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAI AIR CONDITIONINGSinclair
COP at 5°Fbeats 99% · 2.51AO24-12N2-M1Non-ducted, up to 1.5 tonsbeats 95% · 2.35SNCXF-DMO-12-230-HSNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 150%AO35-06N2-M1HNon-ducted, up to 1.5 tonsbeats 95% · 104%SNCXF-DMZ-36-230-HXNon-ducted, 2.5 to 3 tons
HSPF2beats 100% · 15.6AO35-06N2-M1HNon-ducted, up to 1.5 tonsbeats 99% · 11.0SNCXF-DMZ-48-230-HXDucted, 3.5 to 4.5 tons
SEER2beats 100% · 35.0AO35-06N2-M1HNon-ducted, up to 1.5 tonsbeats 96% · 20.4SNCXF-DMZ-48-230-HSDucted, 3.5 to 4.5 tons
EER2beats 99% · 17.4AO35-06N2-M1HNon-ducted, up to 1.5 tonsbeats 96% · 16.0SNCXF-DMO-06-230-HXNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hAO35-18N2-M1HNon-ducted, up to 1.5 tonsbeats 95% · 37,400 Btu/hSNCXF-DMZ-36-230-HXNon-ducted, 2.5 to 3 tons

More comparisons