Both views use the same certified data. This device remembers your choice.
Capella vs Custom Comfort: heat pump ratings compared
Against heat pumps of the same size and type, a typical Capella model beats 70% and a typical Custom Comfort model 71%. Custom Comfort rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Capella
70%
of similar heat pumps beaten by its typical model
Well above average27 models listed
Custom Comfort
71%
of similar heat pumps beaten by its typical model
Well above average28 models listed
- Efficiency on a 5°F dayCOP at 5°FCapella: Beats 55%Custom Comfort: Beats 64%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCapella: Beats 77%Custom Comfort: Beats 72%
- Winter-long heating efficiencyHSPF2Capella: Beats 80%Custom Comfort: Beats 84%
- Summer-long cooling efficiencySEER2Capella: Beats 71%Custom Comfort: Beats 70%
- Hot-day cooling efficiencyEER2Capella: Beats 68%Custom Comfort: Beats 68%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Capella
- 96%
- Custom Comfort
- 96%
Xcel CC
- Capella
- 93%
- Custom Comfort
- 100%
CEE Advanced
- Capella
- 0%
- Custom Comfort
- 4%
ENERGY STAR CC
- Capella
- 93%
- Custom Comfort
- 100%
All-around best, ducted 3.5 to 4.5 tons
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
Capella
- 1CPM5B1-H48A-OCapellaAlso listed as CPM5B1V-H48A-O4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 2CPM5B1-H55A-OCapellaAlso listed as CPM5B1V-H55A-O4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 3CCB1-H48A-Owith ducted air handler CAHB1-H48A-ICapella4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 68.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 16.5 (SEER2)
- Good
- Hot-day cooling
- 10.5 (EER2)
- Below the middle
Custom Comfort
- 1CCOXHBMZ648HPCustom Comfort4 tons · 47,000 Btu/h · DuctedCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 2CCOXHBMZ655HPCustom Comfort4.5 tons · 53,000 Btu/h · DuctedCold-climate pick, score 81.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 87% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.7 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 3CCOXHBSZ48CHPwith ducted air handler CCOXHBSD48Custom Comfort4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 78.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 16.7 (SEER2)
- Good
- Hot-day cooling
- 10.4 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view