Skip to content

Capella vs Custom Comfort heat pumps

Measured against models of the same size and duct type, Capella scores higher on 3 of the 6 ratings. Capella has 27 outdoor models, Custom Comfort has 28 outdoor models. Capella and Custom Comfort have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Capella and Custom Comfort on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Capella scores higher on 3 of the 6 ratings.
  • Capella
  • Custom Comfort
  • Other ranked manufacturers
CapellaCustom C…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCapellaCustom Comfort
Efficiency index70%median —71%median —
COP at 5°F55%median 2.0064%median 2.00
Capacity retention at 5°F77% (higher)median 95%72% (higher)median 91%
HSPF280%median 10.484%median 10.6
SEER271% (higher)median 21.370% (higher)median 20.8
EER268%median 12.368%median 12.3
Heating capacity at 5°F76% (higher)median 21,600 Btu/h72% (higher)median 22,900 Btu/h
Outdoor models2728
AHRI certifications93103

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCapellaCustom Comfort
CEE 2025 Tier 1 (Split ASHP)96.3%26 models96.4%27 models
CEE 2026 Tier 1 (Split ASHP)96.3%26 models96.4%27 models
CEE Advanced Tier (Split ASHP)0%0 models3.6%1 models
Xcel Energy Colorado cold-climate ASHP (2025)92.6%25 models100%28 models
DOE Cold Climate Heat Pump Challenge0%0 models3.6%1 models
ENERGY STAR Cold Climate92.6%25 models100%28 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Capella
  • Custom Comfort
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCapellaCustom Comfort
Ducted, up to 1.5 tons5 · index 79%10 · index 78%
Ducted, 2 tons2 · index 70%4 · index 71%
Ducted, 2.5 to 3 tons6 · index 76%7 · index 73%
Ducted, 3.5 to 4.5 tons6 · index 72%6 · index 64%
Non-ducted, up to 1.5 tons11 · index 65%10 · index 77%
Non-ducted, 2 tons3 · index 57%2 · index 83%
Non-ducted, 2.5 to 3 tons4 · index 77%6 · index 66%
Non-ducted, 3.5 to 4.5 tons4 · index 67%4 · index 51%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCapellaCold-climate score, best modelCustom ComfortCold-climate score, best model
Ducted, up to 1.5 tons82.7(50 is the typical model of its size class)CPPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 21602763093.7(50 is the typical model of its size class) (higher)CCOXHBSZ06HPwith ducted air handler CCOXHBSD0610 of 10 models qualify · AHRI 215745983
Ducted, 2 tons85.8(50 is the typical model of its size class)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models qualify · AHRI 21602763185.8(50 is the typical model of its size class)CCOXHBSZ24HPwith ducted air handler CCOXHBSD244 of 4 models qualify · AHRI 215745987
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models qualify · AHRI 21602763983.5(50 is the typical model of its size class) (higher)CCOXHBSZ36CHPwith ducted air handler CCOXHBSD367 of 7 models qualify · AHRI 215745999
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models qualify · AHRI 21602764282.6(50 is the typical model of its size class)CCOXHBMZ648HP6 of 6 models qualify · AHRI 215746015
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I9 of 11 models qualify · AHRI 21644528197.0(50 is the typical model of its size class) (higher)CCOXHBSZ06HPwith ductless indoor unit CCOXHBWM0610 of 10 models qualify · AHRI 215745973
Non-ducted, 2 tons90.1(50 is the typical model of its size class)CPPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 21602762790.1(50 is the typical model of its size class)CCOXHBSZ24HPwith ductless indoor unit CCOXHB4C242 of 2 models qualify · AHRI 215745982
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models qualify · AHRI 21602764089.4(50 is the typical model of its size class) (higher)CCOXHBSZ36CHPwith ductless indoor unit CCOXHBFC366 of 6 models qualify · AHRI 215746002
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models qualify · AHRI 21602764373.6(50 is the typical model of its size class)CCOXHBMZ648HP4 of 4 models qualify · AHRI 215746016

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCapellaAll-around score, best modelCustom ComfortAll-around score, best model
Ducted, up to 1.5 tons86.9(50 is the typical model of its size class)CPPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 21602762895.0(50 is the typical model of its size class) (higher)CCOXHBSZ06HPwith ducted air handler CCOXHBSD0610 of 10 models have all five ratings · AHRI 215745983
Ducted, 2 tons78.6(50 is the typical model of its size class)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models have all five ratings · AHRI 21602763178.9(50 is the typical model of its size class) (higher)CCOESBSZ24HPwith ducted air handler CCOXHBSD244 of 4 models have all five ratings · AHRI 218425832
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models have all five ratings · AHRI 21602763983.9(50 is the typical model of its size class)CCOXHBMZ536HP7 of 7 models have all five ratings · AHRI 215746012
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models have all five ratings · AHRI 21602764284.3(50 is the typical model of its size class)CCOXHBMZ648HP6 of 6 models have all five ratings · AHRI 215746015
Non-ducted, up to 1.5 tons85.1(50 is the typical model of its size class)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I11 of 11 models have all five ratings · AHRI 21644528196.6(50 is the typical model of its size class) (higher)CCOXHBSZ06HPwith ductless indoor unit CCOXHBWM0610 of 10 models have all five ratings · AHRI 215745973
Non-ducted, 2 tons78.3(50 is the typical model of its size class)CPPB-H24A-Owith ductless indoor unit CPPB-H24A-I3 of 3 models have all five ratings · AHRI 21602762387.8(50 is the typical model of its size class) (higher)CCOESBSZ24HPwith ductless indoor unit CCOXHBWM242 of 2 models have all five ratings · AHRI 217968402
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models have all five ratings · AHRI 21602763878.8(50 is the typical model of its size class)CCOXHBMZ536HP6 of 6 models have all five ratings · AHRI 215746011
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models have all five ratings · AHRI 21602764175.5(50 is the typical model of its size class)CCOXHBMZ648HP4 of 4 models have all five ratings · AHRI 215746014

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCapellaCustom Comfort
COP at 5°Fbeats 95% · 2.34CPPB-H24A-ONon-ducted, 2 tonsbeats 99% · 2.51CCOESBSZ12HPNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 120%CPPB-H09A-ODucted, up to 1.5 tonsbeats 98% · 126%CCOXHBSZ09HPNon-ducted, up to 1.5 tons
HSPF2beats 99% · 11.0CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-ODucted, 3.5 to 4.5 tonsbeats 99% · 14.8CCOXHBSZ06HPNon-ducted, up to 1.5 tons
SEER2beats 96% · 27.4CPPB-H09A-ONon-ducted, up to 1.5 tonsbeats 97% · 25.0CCOESBMZ427HPNon-ducted, 2.5 to 3 tons
EER2beats 95% · 14.0CPPB-H09A-ODucted, up to 1.5 tonsbeats 99% · 18.0CCOXHBSZ06HPNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 39,000 Btu/hCCB1-H36A-ODucted, 2.5 to 3 tonsbeats 98% · 39,500 Btu/hCCOXHBSZ36CHPNon-ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Capella vs Custom Comfort: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Capella (median, middle 50%)
  • Custom Comfort (median, middle 50%)
Heating capacity, % of its 47°F maximum78%74%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Capella: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Capella, 47°F27100%100%100%100%100%
Capella, 17°F2772%75%81%86%94%
Capella, 5°F2763%71%78%82%85%
Capella: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Capella, 47°F272.863.13.223.443.54
Capella, 17°F271.982.122.352.522.6
Capella, 5°F271.861.93222.1
Custom Comfort: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Custom Comfort, 47°F28100%100%100%100%100%
Custom Comfort, 17°F2869%74%79%82%89%
Custom Comfort, 5°F2862%68%74%81%83%
Custom Comfort: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Custom Comfort, 47°F283.13.223.353.523.75
Custom Comfort, 17°F282.022.242.382.552.64
Custom Comfort, 5°F281.89222.32.41

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter