Both views use the same certified data. This device remembers your choice.
Capella vs Stealth heat pumps
Measured against models of the same size and duct type, Capella scores higher on 6 of the 6 ratings. Capella has 27 outdoor models, Stealth has 27 outdoor models. Capella and Stealth have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Capella
- Stealth
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Capella | Stealth |
|---|---|---|
| Efficiency index | 70% (higher)median — | 42% (higher)median — |
| COP at 5°F | 55% (higher)median 2.00 | 37% (higher)median 1.90 |
| Capacity retention at 5°F | 77% (higher)median 95% | 43% (higher)median 74% |
| HSPF2 | 80% (higher)median 10.4 | 52% (higher)median 9.5 |
| SEER2 | 71% (higher)median 21.3 | 48% (higher)median 20.0 |
| EER2 | 68% (higher)median 12.3 | 30% (higher)median 10.5 |
| Heating capacity at 5°F | 76% (higher)median 21,600 Btu/h | 47% (higher)median 18,000 Btu/h |
| Outdoor models | 27 | 27 |
| AHRI certifications | 93 | 34 |
Share of models meeting each standard
| Standard | Capella | Stealth |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 96.3%26 models | 55.6%15 models |
| CEE 2026 Tier 1 (Split ASHP) | 96.3%26 models | 55.6%15 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 92.6%25 models | 55.6%15 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 92.6%25 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Capella
- Stealth
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Capella | Stealth |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 79% | 1 · index 49% |
| Ducted, 2 tons | 2 · index 70% | 1 · index 37% |
| Ducted, 2.5 to 3 tons | 6 · index 76% | 2 · index 42% |
| Ducted, 3.5 to 4.5 tons | 6 · index 72% | 2 · index 51% |
| Non-ducted, up to 1.5 tons | 11 · index 65% | 10 · index 35% |
| Non-ducted, 2 tons | 3 · index 57% | 3 · index 39% |
| Non-ducted, 2.5 to 3 tons | 4 · index 77% | 7 · index 47% |
| Non-ducted, 3.5 to 4.5 tons | 4 · index 67% | 1 · index 50% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CapellaCold-climate score, best model | StealthCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.7(50 is the typical model of its size class) (higher)CPPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 216027630 | 50.0(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-321 of 1 models qualify · AHRI 218729456 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models qualify · AHRI 216027631 | 45.6(50 is the typical model of its size class)AC-24-HP-E-32with ducted air handler AC-24-AH-E-321 of 1 models qualify · AHRI 218729457 |
| Ducted, 2.5 to 3 tons | 82.7(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models qualify · AHRI 216027639 | None on this board (0 of 2 models qualify) |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models qualify · AHRI 216027642 | 72.3(50 is the typical model of its size class)AC-48-HP-E-32with ducted air handler AC-48-AH-E-322 of 2 models qualify · AHRI 218729460 |
| Non-ducted, up to 1.5 tons | 83.4(50 is the typical model of its size class) (higher)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I9 of 11 models qualify · AHRI 216445281 | 66.2(50 is the typical model of its size class)AC-18Z-E-M26 of 10 models qualify · AHRI 218729439 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 216027627 | 68.5(50 is the typical model of its size class)AC-24Z-E-M31 of 3 models qualify · AHRI 218729440 |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models qualify · AHRI 216027640 | 59.7(50 is the typical model of its size class)AC-42Z-E-M55 of 7 models qualify · AHRI 218729443 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models qualify · AHRI 216027643 | 33.3(50 is the typical model of its size class)AC2042K230R3A1 of 1 models qualify · AHRI 218858152 |
All-around best
| Size and duct type | CapellaAll-around score, best model | StealthAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class) (higher)CPPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 216027628 | 48.7(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-321 of 1 models have all five ratings · AHRI 218729456 |
| Ducted, 2 tons | 78.6(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models have all five ratings · AHRI 216027631 | 37.0(50 is the typical model of its size class)AC-24-HP-E-32with ducted air handler AC-24-AH-E-321 of 1 models have all five ratings · AHRI 218729457 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models have all five ratings · AHRI 216027639 | 42.3(50 is the typical model of its size class)AC-36-HP-E-32with ducted air handler AC-36-AH-E-322 of 2 models have all five ratings · AHRI 218729459 |
| Ducted, 3.5 to 4.5 tons | 84.3(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models have all five ratings · AHRI 216027642 | 53.5(50 is the typical model of its size class)AC-48-HP-E-32with ducted air handler AC-48-AH-E-322 of 2 models have all five ratings · AHRI 218729460 |
| Non-ducted, up to 1.5 tons | 85.1(50 is the typical model of its size class) (higher)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I11 of 11 models have all five ratings · AHRI 216445281 | 64.3(50 is the typical model of its size class)AC2018K230R3A10 of 10 models have all five ratings · AHRI 218858149 |
| Non-ducted, 2 tons | 78.3(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ductless indoor unit CPPB-H24A-I3 of 3 models have all five ratings · AHRI 216027623 | 73.3(50 is the typical model of its size class)AC-24Z-E-M33 of 3 models have all five ratings · AHRI 218729440 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models have all five ratings · AHRI 216027638 | 67.4(50 is the typical model of its size class)AC-30Z-E-M47 of 7 models have all five ratings · AHRI 218729441 |
| Non-ducted, 3.5 to 4.5 tons | 75.5(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models have all five ratings · AHRI 216027641 | 49.5(50 is the typical model of its size class)AC2042K230R3A1 of 1 models have all five ratings · AHRI 218858152 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Capella | Stealth |
|---|---|---|
| COP at 5°F | beats 95% · 2.34CPPB-H24A-ONon-ducted, 2 tons | beats 69% · 2.10AC-48-HP-E-32Ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 98% · 120%CPPB-H09A-ODucted, up to 1.5 tons | beats 81% · 90%AC-24Z-E-M3Non-ducted, 2 tons |
| HSPF2 | beats 99% · 11.0CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-ODucted, 3.5 to 4.5 tons | beats 71% · 10.0AC-24Z-E-M3Non-ducted, 2 tons |
| SEER2 | beats 96% · 27.4CPPB-H09A-ONon-ducted, up to 1.5 tons | beats 94% · 24.0AC2042K230R3ANon-ducted, 3.5 to 4.5 tons |
| EER2 | beats 95% · 14.0CPPB-H09A-ODucted, up to 1.5 tons | beats 76% · 12.5AC-30Z-E-M4Non-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 39,000 Btu/hCCB1-H36A-ODucted, 2.5 to 3 tons | beats 86% · 14,500 Btu/hAC-18Z-E-M2Non-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Capella (median, middle 50%)
- Stealth (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Capella, 47°F | 27 | 100% | 100% | 100% | 100% | 100% |
| Capella, 17°F | 27 | 72% | 75% | 81% | 86% | 94% |
| Capella, 5°F | 27 | 63% | 71% | 78% | 82% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Capella, 47°F | 27 | 2.86 | 3.1 | 3.22 | 3.44 | 3.54 |
| Capella, 17°F | 27 | 1.98 | 2.12 | 2.35 | 2.52 | 2.6 |
| Capella, 5°F | 27 | 1.86 | 1.93 | 2 | 2 | 2.1 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Stealth, 47°F | 15 | 100% | 100% | 100% | 100% | 100% |
| Stealth, 17°F | 15 | 67% | 70% | 76% | 78% | 82% |
| Stealth, 5°F | 15 | 66% | 67% | 70% | 72% | 73% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Stealth, 47°F | 15 | 3 | 3.13 | 3.33 | 3.55 | 3.67 |
| Stealth, 17°F | 15 | 2.04 | 2.1 | 2.2 | 2.3 | 2.34 |
| Stealth, 5°F | 15 | 1.93 | 2 | 2 | 2 | 2 |
Source: NEEP ccASHP list · as of