Skip to content

Capella vs Stealth heat pumps

Measured against models of the same size and duct type, Capella scores higher on 6 of the 6 ratings. Capella has 27 outdoor models, Stealth has 27 outdoor models. Capella and Stealth have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Capella and Stealth on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Capella scores higher on 6 of the 6 ratings.
  • Capella
  • Stealth
  • Other ranked manufacturers
CapellaStealth

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCapellaStealth
Efficiency index70% (higher)median —42% (higher)median —
COP at 5°F55% (higher)median 2.0037% (higher)median 1.90
Capacity retention at 5°F77% (higher)median 95%43% (higher)median 74%
HSPF280% (higher)median 10.452% (higher)median 9.5
SEER271% (higher)median 21.348% (higher)median 20.0
EER268% (higher)median 12.330% (higher)median 10.5
Heating capacity at 5°F76% (higher)median 21,600 Btu/h47% (higher)median 18,000 Btu/h
Outdoor models2727
AHRI certifications9334

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCapellaStealth
CEE 2025 Tier 1 (Split ASHP)96.3%26 models55.6%15 models
CEE 2026 Tier 1 (Split ASHP)96.3%26 models55.6%15 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)92.6%25 models55.6%15 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate92.6%25 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Capella
  • Stealth
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCapellaStealth
Ducted, up to 1.5 tons5 · index 79%1 · index 49%
Ducted, 2 tons2 · index 70%1 · index 37%
Ducted, 2.5 to 3 tons6 · index 76%2 · index 42%
Ducted, 3.5 to 4.5 tons6 · index 72%2 · index 51%
Non-ducted, up to 1.5 tons11 · index 65%10 · index 35%
Non-ducted, 2 tons3 · index 57%3 · index 39%
Non-ducted, 2.5 to 3 tons4 · index 77%7 · index 47%
Non-ducted, 3.5 to 4.5 tons4 · index 67%1 · index 50%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCapellaCold-climate score, best modelStealthCold-climate score, best model
Ducted, up to 1.5 tons82.7(50 is the typical model of its size class) (higher)CPPB-H18A-Owith ducted air handler SFCB1-H18A-I5 of 5 models qualify · AHRI 21602763050.0(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-321 of 1 models qualify · AHRI 218729456
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models qualify · AHRI 21602763145.6(50 is the typical model of its size class)AC-24-HP-E-32with ducted air handler AC-24-AH-E-321 of 1 models qualify · AHRI 218729457
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models qualify · AHRI 216027639None on this board (0 of 2 models qualify)
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models qualify · AHRI 21602764272.3(50 is the typical model of its size class)AC-48-HP-E-32with ducted air handler AC-48-AH-E-322 of 2 models qualify · AHRI 218729460
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class) (higher)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I9 of 11 models qualify · AHRI 21644528166.2(50 is the typical model of its size class)AC-18Z-E-M26 of 10 models qualify · AHRI 218729439
Non-ducted, 2 tons90.1(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ductless indoor unit SICB1-H24A-I3 of 3 models qualify · AHRI 21602762768.5(50 is the typical model of its size class)AC-24Z-E-M31 of 3 models qualify · AHRI 218729440
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models qualify · AHRI 21602764059.7(50 is the typical model of its size class)AC-42Z-E-M55 of 7 models qualify · AHRI 218729443
Non-ducted, 3.5 to 4.5 tons73.6(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models qualify · AHRI 21602764333.3(50 is the typical model of its size class)AC2042K230R3A1 of 1 models qualify · AHRI 218858152

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCapellaAll-around score, best modelStealthAll-around score, best model
Ducted, up to 1.5 tons86.9(50 is the typical model of its size class) (higher)CPPB-H09A-Owith ducted air handler SFCB1-H09A-I5 of 5 models have all five ratings · AHRI 21602762848.7(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-321 of 1 models have all five ratings · AHRI 218729456
Ducted, 2 tons78.6(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ducted air handler SFCB1-H24A-I2 of 2 models have all five ratings · AHRI 21602763137.0(50 is the typical model of its size class)AC-24-HP-E-32with ducted air handler AC-24-AH-E-321 of 1 models have all five ratings · AHRI 218729457
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O6 of 6 models have all five ratings · AHRI 21602763942.3(50 is the typical model of its size class)AC-36-HP-E-32with ducted air handler AC-36-AH-E-322 of 2 models have all five ratings · AHRI 218729459
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O6 of 6 models have all five ratings · AHRI 21602764253.5(50 is the typical model of its size class)AC-48-HP-E-32with ducted air handler AC-48-AH-E-322 of 2 models have all five ratings · AHRI 218729460
Non-ducted, up to 1.5 tons85.1(50 is the typical model of its size class) (higher)CPEB-H09A-Owith ductless indoor unit CPEB-H09A-I11 of 11 models have all five ratings · AHRI 21644528164.3(50 is the typical model of its size class)AC2018K230R3A10 of 10 models have all five ratings · AHRI 218858149
Non-ducted, 2 tons78.3(50 is the typical model of its size class) (higher)CPPB-H24A-Owith ductless indoor unit CPPB-H24A-I3 of 3 models have all five ratings · AHRI 21602762373.3(50 is the typical model of its size class)AC-24Z-E-M33 of 3 models have all five ratings · AHRI 218729440
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)CPM4B1-H36A-OAlso listed as CPM4B1V-H36A-O4 of 4 models have all five ratings · AHRI 21602763867.4(50 is the typical model of its size class)AC-30Z-E-M47 of 7 models have all five ratings · AHRI 218729441
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class) (higher)CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-O4 of 4 models have all five ratings · AHRI 21602764149.5(50 is the typical model of its size class)AC2042K230R3A1 of 1 models have all five ratings · AHRI 218858152

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCapellaStealth
COP at 5°Fbeats 95% · 2.34CPPB-H24A-ONon-ducted, 2 tonsbeats 69% · 2.10AC-48-HP-E-32Ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 98% · 120%CPPB-H09A-ODucted, up to 1.5 tonsbeats 81% · 90%AC-24Z-E-M3Non-ducted, 2 tons
HSPF2beats 99% · 11.0CPM5B1-H48A-OAlso listed as CPM5B1V-H48A-ODucted, 3.5 to 4.5 tonsbeats 71% · 10.0AC-24Z-E-M3Non-ducted, 2 tons
SEER2beats 96% · 27.4CPPB-H09A-ONon-ducted, up to 1.5 tonsbeats 94% · 24.0AC2042K230R3ANon-ducted, 3.5 to 4.5 tons
EER2beats 95% · 14.0CPPB-H09A-ODucted, up to 1.5 tonsbeats 76% · 12.5AC-30Z-E-M4Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 98% · 39,000 Btu/hCCB1-H36A-ODucted, 2.5 to 3 tonsbeats 86% · 14,500 Btu/hAC-18Z-E-M2Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Capella vs Stealth: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Capella (median, middle 50%)
  • Stealth (median, middle 50%)
Heating capacity, % of its 47°F maximum78%70%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Capella: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Capella, 47°F27100%100%100%100%100%
Capella, 17°F2772%75%81%86%94%
Capella, 5°F2763%71%78%82%85%
Capella: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Capella, 47°F272.863.13.223.443.54
Capella, 17°F271.982.122.352.522.6
Capella, 5°F271.861.93222.1
Stealth: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Stealth, 47°F15100%100%100%100%100%
Stealth, 17°F1567%70%76%78%82%
Stealth, 5°F1566%67%70%72%73%
Stealth: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Stealth, 47°F1533.133.333.553.67
Stealth, 17°F152.042.12.22.32.34
Stealth, 5°F151.932222

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter