Skip to content

Carrier vs Cooper&Hunter: heat pump ratings compared

Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Cooper&Hunter model 65%. Cooper&Hunter rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Carrier

49%

of similar heat pumps beaten by its typical model

About average

846 models listed

Cooper&Hunter

65%

of similar heat pumps beaten by its typical model

Well above average

63 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Cooper&Hunter: Beats 66%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Cooper&Hunter: Beats 63%
  • Winter-long heating efficiencyHSPF2Carrier: Beats 41%Cooper&Hunter: Beats 74%
  • Summer-long cooling efficiencySEER2Carrier: Beats 43%Cooper&Hunter: Beats 66%
  • Hot-day cooling efficiencyEER2Carrier: Beats 60%Cooper&Hunter: Beats 59%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Carrier
    42%
    Cooper&Hunter
    86%
  • Xcel CC

    Carrier
    29%
    Cooper&Hunter
    73%
  • CEE Advanced

    Carrier
    1%
    Cooper&Hunter
    8%
  • ENERGY STAR CC

    Carrier
    27%
    Cooper&Hunter
    71%

All-around best, ducted 5 tons and up

Carrier

  1. 127VNA360A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 82.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.18 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    89.3score / 100Heating 83 · Cooling 96
  2. 2H5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCONCarrier (sold as HEIL)Also sold as Comfortmaker C5H3V60*K*AAA, Kenmore (C,H,T)5H3V60*K*AAA, Tempstar T5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 73.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.06 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.5 (EER2)
    Top 10%
    84.2score / 100Heating 72 · Cooling 96
  3. 327VPA960A*030*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 249VAN060**AA, Arcoaire N5H9V60*K*AAA, Arcoaire Q5H9V60*K*AAA5 tons · 57,500 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.12 (COP at 5°F)
    Great
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    80.8score / 100Heating 81 · Cooling 81

Cooper&Hunter

  1. 1CHV6-RS60URBMHHCooper&Hunter (sold as Cooper & Hunter)5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 88.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.1 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    70.8score / 100Heating 89 · Cooling 53
  2. 2CH-R60LCU-230VOwith ducted air handler CH-RS60LCDT-HSCooper&Hunter5 tons · 58,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    9.7 (HSPF2)
    Top 10%
    Cooling efficiency
    17.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    65.9score / 100Heating 84 · Cooling 48
  3. 3CH-R60MES-230VOCooper&Hunter5 tons · 60,000 Btu/h · DuctedNot a cold-climate pick: keeps 66% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.2 (HSPF2)
    Great
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    63.2score / 100Heating 73 · Cooling 54

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter