Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Carrier vs Cooper&Hunter heat pumps
Measured against models of the same size and duct type, Cooper&Hunter scores higher on 5 of the 6 ratings. Carrier has 816 outdoor models, Cooper&Hunter has 63 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Carrier
- Cooper&Hunter
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Carrier | Cooper&Hunter |
|---|---|---|
| Efficiency index | 48%median — · 23rd ranked | 64%median — · 1st ranked |
| COP at 5°F | 56%median 2.04 · 16th ranked | 65%median 2.10 · 3rd ranked |
| Capacity retention at 5°F | 34%median 53% · 28th ranked | 62%median 80% · 5th ranked |
| HSPF2 | 40%median 7.8 · 25th ranked | 73%median 10.2 · 1st ranked |
| SEER2 | 42%median 15.2 · 23rd ranked | 65%median 21.0 · 2nd ranked |
| EER2 | 59% (higher)median 11.5 · 8th ranked | 58% (higher)median 12.0 · 9th ranked |
| Heating capacity at 5°F | 37%median 18,600 Btu/h · 27th ranked | 65%median 24,000 Btu/h · 5th ranked |
| Outdoor models | 816 | 63 |
| AHRI certifications | 521,403 | 260 |
Share of models meeting each standard
| Standard | Carrier | Cooper&Hunter |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 40.2%328 models | 85.7%54 models |
| CEE 2026 Tier 1 (Split ASHP) | 35.3%288 models | 84.1%53 models |
| CEE Advanced Tier (Split ASHP) | 1%8 models | 7.9%5 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 27.2%222 models | 73%46 models |
| DOE Cold Climate Heat Pump Challenge | 1%8 models | 7.9%5 models |
| ENERGY STAR Cold Climate | 26.7%218 models | 71.4%45 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Carrier
- Cooper&Hunter
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Carrier | Cooper&Hunter |
|---|---|---|
| Ducted, up to 1.5 tons | 69 · index 56% | 12 · index 74% |
| Ducted, 2 tons | 93 · index 47% | 6 · index 62% |
| Ducted, 2.5–3 tons | 228 · index 45% | 15 · index 67% |
| Ducted, 3.5–4.5 tons | 306 · index 44% | 14 · index 67% |
| Ducted, 5 tons and up | 68 · index 50% | 3 · index 66% |
| Non-ducted, up to 1.5 tons | 54 · index 59% | 20 · index 65% |
| Non-ducted, 2 tons | 16 · index 57% | 4 · index 60% |
| Non-ducted, 2.5–3 tons | 30 · index 55% | 13 · index 62% |
| Non-ducted, 3.5–4.5 tons | 22 · index 47% | 11 · index 50% |
| Non-ducted, 5 tons and up | 4 · index 57% | 2 · index 71% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CarrierCold-climate score, best model | Cooper&HunterCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.5(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK30 of 68 models qualify · AHRI 215323798 | 93.5(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 215864212 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK44 of 94 models qualify · AHRI 215323817 | 85.7(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 215864219 |
| Ducted, 2.5–3 tons | 83.2(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK59 of 229 models qualify · AHRI 215357119 | 84.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 217026552 |
| Ducted, 3.5–4.5 tons | 89.7(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A63 of 293 models qualify · AHRI 218372714 | 82.7(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 215864279 |
| Ducted, 5 tons and up | 94.7(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 80 models qualify · AHRI 216763249 | 88.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558 |
| Non-ducted, up to 1.5 tons | 96.8(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK35 of 54 models qualify · AHRI 215413214 | 96.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 215864172 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK15 of 16 models qualify · AHRI 215323815 | 89.4(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 215864191 |
| Non-ducted, 2.5–3 tons | 89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK21 of 30 models qualify · AHRI 215323843 | 92.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 217026553 |
| Non-ducted, 3.5–4.5 tons | 79.4(50 is the typical model of its size class)RAV-BP421AT2P-ULwith ductless indoor unit RAV-HB421CTP-UL18 of 22 models qualify · AHRI 216415472 | 94.6(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 217026556 |
| Non-ducted, 5 tons and up | 50.6(50 is the typical model of its size class)37VMB060HDS3-11 of 4 models qualify · AHRI 216369714 | 98.2(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559 |
All-around best
| Size and duct type | CarrierAll-around score, best model | Cooper&HunterAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.6(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK64 of 68 models have all five ratings · AHRI 215323798 | 95.0(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 215864212 |
| Ducted, 2 tons | 82.9(50 is the typical model of its size class) (higher)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA90 of 90 models have all five ratings · AHRI 217624252 | 78.8(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 215864228 |
| Ducted, 2.5–3 tons | 88.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL209 of 230 models have all five ratings · AHRI 216415477 | 83.6(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 215864276 |
| Ducted, 3.5–4.5 tons | 90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA241 of 275 models have all five ratings · AHRI 215587917 | 85.1(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 215864264 |
| Ducted, 5 tons and up | 89.1(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA81 of 101 models have all five ratings · AHRI 215931484 | 70.5(50 is the typical model of its size class)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 217026558 |
| Non-ducted, up to 1.5 tons | 96.5(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK51 of 54 models have all five ratings · AHRI 215323742 | 96.2(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 215864172 |
| Non-ducted, 2 tons | 88.5(50 is the typical model of its size class) (higher)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK15 of 16 models have all five ratings · AHRI 215323752 | 86.8(50 is the typical model of its size class)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 215864171 |
| Non-ducted, 2.5–3 tons | 91.0(50 is the typical model of its size class) (higher)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL29 of 30 models have all five ratings · AHRI 216415465 | 86.7(50 is the typical model of its size class)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 217026553 |
| Non-ducted, 3.5–4.5 tons | 84.9(50 is the typical model of its size class) (higher)MCY-MUB0488HS2P-UL20 of 22 models have all five ratings · AHRI 216760288 | 82.7(50 is the typical model of its size class)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 217026556 |
| Non-ducted, 5 tons and up | 69.0(50 is the typical model of its size class)MCY-MUB0608HS2P-UL4 of 4 models have all five ratings · AHRI 216763251 | 83.5(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 217026559 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Carrier | Cooper&Hunter |
|---|---|---|
| COP at 5°F | beats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5–4.5 tons | beats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tons | beats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and up |
| HSPF2 | beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tons | beats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tons | beats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5–3 tons |
| EER2 | beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5–3 tons | beats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5–4.5 tons | beats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and up |