Skip to content

Carrier vs Cooper&Hunter: heat pump ratings compared

Against heat pumps of the same size and type, a typical Carrier model beats 48% and a typical Cooper&Hunter model 64%. Cooper&Hunter rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Carrier

48%

of similar heat pumps beaten by its typical model

About average

816 models listed

Cooper&Hunter

64%

of similar heat pumps beaten by its typical model

Well above average

63 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 56%Cooper&Hunter: Beats 65%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 34%Cooper&Hunter: Beats 62%
  • Winter-long heating efficiencyHSPF2Carrier: Beats 40%Cooper&Hunter: Beats 73%
  • Summer-long cooling efficiencySEER2Carrier: Beats 42%Cooper&Hunter: Beats 65%
  • Hot-day cooling efficiencyEER2Carrier: Beats 59%Cooper&Hunter: Beats 58%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Carrier
    40%
    Cooper&Hunter
    86%
  • Xcel CC

    Carrier
    27%
    Cooper&Hunter
    73%
  • CEE Advanced

    Carrier
    1%
    Cooper&Hunter
    8%
  • ENERGY STAR CC

    Carrier
    27%
    Cooper&Hunter
    71%

All-around best, ducted up to 1.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Carrier

  1. 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3CarrierAlso sold as Arcoaire D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    21.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.5 (EER2)
    Top 10%
    95.6score / 100Heating 94 · Cooling 98
  2. 237MAHAQ09AA3with ducted air handler 45MBDAQ12XA3CarrierAlso sold as Arcoaire D5CSHAH09AAK1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    112% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.89 (COP at 5°F)
    Below the middle
    Winter efficiency
    12.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.5 (SEER2)
    Top 10%
    Hot-day cooling
    13.5 (EER2)
    Top 10%
    87.4score / 100Heating 80 · Cooling 95
  3. 337MARAQ09AA3with ducted air handler 45MBDAQ12XH3CarrierAlso sold as Arcoaire D5CSRAH09AAK1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.32 (COP at 5°F)
    Great
    Winter efficiency
    11.5 (HSPF2)
    Top 10%
    Cooling efficiency
    19.8 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Great
    81.0score / 100Heating 81 · Cooling 81

Cooper&Hunter

  1. 1CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MSCooper&Hunter0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Winter efficiency
    13.8 (HSPF2)
    Top 10%
    Cooling efficiency
    21.4 (SEER2)
    Top 10%
    Hot-day cooling
    14.4 (EER2)
    Top 10%
    95.0score / 100Heating 94 · Cooling 97
  2. 2CH-RHP09-230VOwith ducted air handler CH-RS09MDT-MSCooper&Hunter1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    112% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.89 (COP at 5°F)
    Below the middle
    Winter efficiency
    12.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.4 (SEER2)
    Top 10%
    Hot-day cooling
    13.4 (EER2)
    Top 10%
    86.7score / 100Heating 80 · Cooling 94
  3. 3CH-PQ18-230VOwith ducted air handler CH-STM18AHU24VCooper&Hunter1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 86.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.8 (HSPF2)
    Top 10%
    Cooling efficiency
    19.3 (SEER2)
    Good
    Hot-day cooling
    12.1 (EER2)
    Great
    79.8score / 100Heating 87 · Cooling 73

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view