Carrier vs Mitsubishi Electric: heat pump ratings compared
Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Mitsubishi Electric model 61%. Mitsubishi Electric rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Carrier
49%
of similar heat pumps beaten by its typical model
About average846 models listed
Mitsubishi Electric
61%
of similar heat pumps beaten by its typical model
Well above average156 models listed
- Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Mitsubishi Electric: Beats 56%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Mitsubishi Electric: Beats 55%
- Winter-long heating efficiencyHSPF2Carrier: Beats 41%Mitsubishi Electric: Beats 67%
- Summer-long cooling efficiencySEER2Carrier: Beats 43%Mitsubishi Electric: Beats 63%
- Hot-day cooling efficiencyEER2Carrier: Beats 60%Mitsubishi Electric: Beats 61%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Carrier
- 42%
- Mitsubishi Electric
- 81%
Xcel CC
- Carrier
- 29%
- Mitsubishi Electric
- 67%
CEE Advanced
- Carrier
- 1%
- Mitsubishi Electric
- 10%
ENERGY STAR CC
- Carrier
- 27%
- Mitsubishi Electric
- 66%
All-around best, ducted 5 tons and up
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
Carrier
- 127VNA360A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 82.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 2H5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCONCarrier (sold as HEIL)Also sold as Comfortmaker C5H3V60*K*AAA, Kenmore (C,H,T)5H3V60*K*AAA, Tempstar T5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedCold-climate pick, score 73.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 8.5 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.5 (EER2)
- Top 10%
- 327VPA960A*030*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 249VAN060**AA, Arcoaire N5H9V60*K*AAA, Arcoaire Q5H9V60*K*AAA5 tons · 57,500 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Great
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
Mitsubishi Electric
- 1MXZ-SM60NLHZ-**Mitsubishi Electric5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 78.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 10.2 (EER2)
- Below the middle
- 2MXZ-SM60NL-**Mitsubishi Electric5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 72.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 17.0 (SEER2)
- Great
- Hot-day cooling
- 10.2 (EER2)
- Below the middle
- 3MXZ-SM60NLHZ***Mitsubishi ElectricAlso listed as PUMY-HL60NKMU5 tons · 60,000 Btu/h · DuctedCold-climate pick, score 74.0Meets ENERGY STAR CC
- Heat kept at 5°F
- 91% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 16.4 (SEER2)
- Good
- Hot-day cooling
- 9.4 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.