Skip to content

Carrier vs Mitsubishi Electric heat pumps

Measured against models of the same size and duct type, Mitsubishi Electric scores higher on 5 of the 6 ratings. Carrier has 846 outdoor models, Mitsubishi Electric has 156 outdoor models.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Mitsubishi Electric on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsubishi Electric scores higher on 5 of the 6 ratings.
  • Carrier
  • Mitsubishi Electric
  • Other ranked manufacturers
CarrierMitsubis…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierMitsubishi Electric
Efficiency index49%median — · 23rd ranked61%median — · 6th ranked
COP at 5°F57% (higher)median 2.04 · 15th ranked56% (higher)median 2.01 · 16th ranked
Capacity retention at 5°F36%median 55% · 28th ranked55%median 71% · 13th ranked
HSPF241%median 7.8 · 24th ranked67%median 10.0 · 5th ranked
SEER243%median 15.3 · 23rd ranked63%median 20.0 · 3rd ranked
EER260%median 11.5 · 8th ranked61%median 12.5 · 7th ranked
Heating capacity at 5°F39%median 18,600 Btu/h · 27th ranked64%median 20,500 Btu/h · 6th ranked
Outdoor models846156
AHRI certifications589,089538

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierMitsubishi Electric
CEE 2025 Tier 1 (Split ASHP)41.8%354 models80.8%126 models
CEE 2026 Tier 1 (Split ASHP)37%313 models80.8%126 models
CEE Advanced Tier (Split ASHP)1.1%9 models10.3%16 models
Xcel Energy Colorado cold-climate ASHP (2025)29.1%246 models66.7%104 models
DOE Cold Climate Heat Pump Challenge1.1%9 models10.3%16 models
ENERGY STAR Cold Climate27.4%232 models66%103 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 10 groups where both have models
  • Carrier
  • Mitsubishi Electric
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierMitsubishi Electric
Ducted, up to 1.5 tons76 · index 59%24 · index 63%
Ducted, 2 tons99 · index 47%11 · index 59%
Ducted, 2.5 to 3 tons232 · index 46%29 · index 62%
Ducted, 3.5 to 4.5 tons311 · index 45%29 · index 56%
Ducted, 5 tons and up69 · index 51%10 · index 54%
Non-ducted, up to 1.5 tons65 · index 60%60 · index 65%
Non-ducted, 2 tons18 · index 58%13 · index 63%
Non-ducted, 2.5 to 3 tons37 · index 56%21 · index 61%
Non-ducted, 3.5 to 4.5 tons25 · index 50%18 · index 54%
Non-ducted, 5 tons and up5 · index 58%6 · index 66%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelMitsubishi ElectricCold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK35 of 75 models qualify · AHRI 21532379885.9(50 is the typical model of its size class)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL11 of 24 models qualify · AHRI 215734918
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as Arcoaire D5CSHAH24AAK49 of 99 models qualify · AHRI 21532381780.9(50 is the typical model of its size class)PUZ-AK24NLHZ2***with ducted air handler PAA-AA24NL8 of 10 models qualify · AHRI 218697033
Ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class)37MGHAQ36EA3Also sold as Arcoaire D5CMHAH36EAK65 of 235 models qualify · AHRI 21535711988.5(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL20 of 30 models qualify · AHRI 218697041
Ducted, 3.5 to 4.5 tons89.5(50 is the typical model of its size class) (higher)H5H0V48*K*AAA*with indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120A67 of 297 models qualify · AHRI 21837271480.1(50 is the typical model of its size class)MXZ-SM48NLHZ-**18 of 29 models qualify · AHRI 217135880
Ducted, 5 tons and up94.8(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL19 of 81 models qualify · AHRI 21676324978.8(50 is the typical model of its size class)MXZ-SM60NLHZ-**6 of 10 models qualify · AHRI 217643004
Non-ducted, up to 1.5 tons97.1(50 is the typical model of its size class)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK42 of 65 models qualify · AHRI 21541321497.7(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ243 of 60 models qualify · AHRI 215611124
Non-ducted, 2 tons90.1(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as Arcoaire D5CSHAH24AAK17 of 18 models qualify · AHRI 21532381590.5(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL10 of 13 models qualify · AHRI 218697024
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as Arcoaire D5CLHAH36AAK26 of 37 models qualify · AHRI 21532384394.0(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL12 of 21 models qualify · AHRI 218697037
Non-ducted, 3.5 to 4.5 tons75.6(50 is the typical model of its size class)37MGHAQ48FA3Also sold as Arcoaire D5CMHAH48FAK19 of 25 models qualify · AHRI 21535712378.4(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-13 of 18 models qualify · AHRI 215685467
Non-ducted, 5 tons and up52.1(50 is the typical model of its size class)37VMB060HDS3-11 of 5 models qualify · AHRI 21636971469.7(50 is the typical model of its size class) (higher)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models qualify · AHRI 217643000

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelMitsubishi ElectricAll-around score, best model
Ducted, up to 1.5 tons95.7(50 is the typical model of its size class) (higher)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as Arcoaire D5CSHAH06AAK70 of 75 models have all five ratings · AHRI 21532379879.2(50 is the typical model of its size class)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL23 of 23 models have all five ratings · AHRI 215734918
Ducted, 2 tons82.8(50 is the typical model of its size class)27VNA324A*030*with ducted air handler FE5BN(B,X)C36L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN024**AA, HEIL B5H3V24*K*AAA93 of 93 models have all five ratings · AHRI 21762425284.6(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NL11 of 11 models have all five ratings · AHRI 218697028
Ducted, 2.5 to 3 tons88.0(50 is the typical model of its size class)RAV-BP301AT2P-ULwith ducted air handler RAV-HB301BTP-UL216 of 237 models have all five ratings · AHRI 21641547793.8(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL30 of 30 models have all five ratings · AHRI 218697041
Ducted, 3.5 to 4.5 tons90.4(50 is the typical model of its size class) (higher)27VNA154A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA245 of 280 models have all five ratings · AHRI 21558791770.7(50 is the typical model of its size class)MXZ-SM48NLHZ-**29 of 29 models have all five ratings · AHRI 217135880
Ducted, 5 tons and up89.3(50 is the typical model of its size class) (higher)27VNA360A*030*with ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA82 of 102 models have all five ratings · AHRI 21593148465.7(50 is the typical model of its size class)MXZ-SM60NLHZ-**10 of 10 models have all five ratings · AHRI 217643004
Non-ducted, up to 1.5 tons96.9(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit 45MAHAQ06XA3Also sold as Arcoaire D5CSHAH06AAK61 of 65 models have all five ratings · AHRI 21532374298.8(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ256 of 60 models have all five ratings · AHRI 215611124
Non-ducted, 2 tons89.4(50 is the typical model of its size class)37MARAQ24AA3with ductless indoor unit 45MAHAQ24XA3Also sold as Arcoaire D5CSRAH24AAK17 of 18 models have all five ratings · AHRI 21532375289.4(50 is the typical model of its size class)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL12 of 13 models have all five ratings · AHRI 218697024
Non-ducted, 2.5 to 3 tons91.1(50 is the typical model of its size class)RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-UL36 of 37 models have all five ratings · AHRI 21641546592.9(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL21 of 21 models have all five ratings · AHRI 218697037
Non-ducted, 3.5 to 4.5 tons84.9(50 is the typical model of its size class)MCY-MUB0488HS2P-UL21 of 25 models have all five ratings · AHRI 21676028885.7(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-18 of 18 models have all five ratings · AHRI 215685467
Non-ducted, 5 tons and up69.5(50 is the typical model of its size class) (higher)MCY-MUB0608HS2P-UL5 of 5 models have all five ratings · AHRI 21676325168.7(50 is the typical model of its size class)MXZ-SM60NLHZ***Also listed as MXZ-SM60NLHZ-, PUMY-HL60NKMU6 of 6 models have all five ratings · AHRI 217643000

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierMitsubishi Electric
COP at 5°Fbeats 100% · 2.50MCY-MUB0488HS2P-ULNon-ducted, 3.5 to 4.5 tonsbeats 100% · 2.74PUZ-AK42NL2***Non-ducted, 3.5 to 4.5 tons
Capacity retention at 5°Fbeats 100% · 150%37MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 99% · 140%MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
HSPF2beats 100% · 15.637MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 12.0MXZ-SM36NLHZ***Also listed as PUMY-HL36NKMU, MXZ-SM36NLHZ-Non-ducted, 2.5 to 3 tons
SEER2beats 100% · 35.137MPRAQ06AA3Non-ducted, up to 1.5 tonsbeats 100% · 35.0MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
EER2beats 100% · 17.2MCY-MUB0368HS2P-ULNon-ducted, 2.5 to 3 tonsbeats 100% · 21.5MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 61,000 Btu/hH5H0V60*K*AAA*Ducted, 3.5 to 4.5 tonsbeats 100% · 26,600 Btu/hMUZ-FX24NLHZ***Also listed as MUZ-FX24NLHZ2Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Carrier vs Mitsubishi Electric: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Carrier (median, middle 50%)
  • Mitsubishi Electric (median, middle 50%)
Heating capacity, % of its 47°F maximum70%69%COP at maximum capacity2.022.05

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Carrier: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F256100%100%100%100%100%
Carrier, 17°F25665%71%78%85%91%
Carrier, 5°F25657%62%70%78%82%
Carrier: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Carrier, 47°F2562.873.093.233.523.63
Carrier, 17°F2562.122.242.382.522.65
Carrier, 5°F2561.851.992.022.152.32
Mitsubishi Electric: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsubishi Electric, 47°F134100%100%100%100%100%
Mitsubishi Electric, 17°F13458%64%73%87%94%
Mitsubishi Electric, 5°F13451%55%69%85%95%
Mitsubishi Electric: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsubishi Electric, 47°F1342.232.723.23.784.1
Mitsubishi Electric, 17°F1341.7922.242.612.87
Mitsubishi Electric, 5°F1341.81.82.052.22.53

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy