Both views use the same certified data. This device remembers your choice.
Carrier vs Mitsubishi Electric: heat pump ratings compared
Against heat pumps of the same size and type, a typical Carrier model beats 49% and a typical Mitsubishi Electric model 61%. Mitsubishi Electric rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Carrier
49%
of similar heat pumps beaten by its typical model
About average846 models listed
Mitsubishi Electric
61%
of similar heat pumps beaten by its typical model
Well above average156 models listed
- Efficiency on a 5°F dayCOP at 5°FCarrier: Beats 57%Mitsubishi Electric: Beats 56%
- Heating power kept at 5°FCapacity at 5°F vs 47°FCarrier: Beats 36%Mitsubishi Electric: Beats 55%
- Winter-long heating efficiencyHSPF2Carrier: Beats 41%Mitsubishi Electric: Beats 67%
- Summer-long cooling efficiencySEER2Carrier: Beats 43%Mitsubishi Electric: Beats 63%
- Hot-day cooling efficiencyEER2Carrier: Beats 60%Mitsubishi Electric: Beats 61%
Average (50%)Dashed outline: the other brand, for comparison
Rebate standards
CEE 2025
- Carrier
- 42%
- Mitsubishi Electric
- 81%
Xcel CC
- Carrier
- 29%
- Mitsubishi Electric
- 67%
CEE Advanced
- Carrier
- 1%
- Mitsubishi Electric
- 10%
ENERGY STAR CC
- Carrier
- 27%
- Mitsubishi Electric
- 66%
All-around best, ducted up to 1.5 tons
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Carrier
- 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3CarrierAlso sold as Arcoaire D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 13.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 14.5 (EER2)
- Top 10%
- 2W5HD606K1X1Awith ducted air handler W5GLW06K1AAACarrier (sold as Grandaire)0.5 tons · 6,500 Btu/h · DuctedCold-climate pick, score 93.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 13.8 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.4 (SEER2)
- Top 10%
- Hot-day cooling
- 14.4 (EER2)
- Top 10%
- 337MAHAQ09AA3with ducted air handler 45MBDAQ12XA3CarrierAlso sold as Arcoaire D5CSHAH09AAK1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 112% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Winter efficiency
- 12.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 13.5 (EER2)
- Top 10%
Mitsubishi Electric
- 1SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NLMitsubishi Electric1.5 tons · 15,000 Btu/h · DuctedCold-climate pick, score 85.9Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Great
- Winter efficiency
- 10.2 (HSPF2)
- Great
- Cooling efficiency
- 17.2 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2SUZ-AA18NLHZ***with ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 83.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 111% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 12.8 (EER2)
- Great
- 3SUZ-AA12NLHZ***with ducted air handler PEAD-AA12NLMitsubishi Electric1 ton · 12,000 Btu/h · DuctedCold-climate pick, score 76.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 13.6 (EER2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.
Open the advanced view